- ページ 3
送信機 ADEMCO 5804BDVのPDF インストレーション・インストラクションをオンラインで閲覧またはダウンロードできます。ADEMCO 5804BDV 4 ページ。 Two way wireless key with voice status
Operating the Buttons
To Activate a Function
To activate a programmed function, press and hold the associated button down until the yellow LED flashes; then release it.
LED
LED Condition
Red
On Steady
Flashing
Green
On Steady
Flashing
Yellow (Right)
Flashing
Yellow (Left)
Flashing
Red & Green
Alternately
Flashing
N/A
N/A
To Request System Status
Because the 5804BDV is a two-way device, users can check
the system status before arming or disarming their system. To
check
system
status,
momentarily. The yellow LED will flash after you release the
button. After a second or two, the 5804BDV will display the
system status information using a combination of LED and
sounder activity (see the System Status Indications Table). If
5804BDV does not receive system status information from the
panel for approximately 5 seconds, it will shut itself down. It will
also shut itself down if there is no button activity within 5
seconds of receiving a status update.
This device may not receive the system status
properly if it operates within a few feet of the
5881 RF receiver.
WARNING!
Multiple Button Operations
The 5804BDV should not be used for 24-hour
silent alarm, as the unit itself is not silent.
WARNING!
The 5804BDV can generate the same responses as keypad
panic key pairs of [✶] + [#] and [✶] + [1] by depressing "A" + "C"
and "B" + "D" button pairs, respectively.
FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION INSTRUCTIONS FOR THE
CONTROL WITH WHICH THIS DEVICE IS USED.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
System Status Indications Table
System Armed Away
System Armed Stay
Fire Fire Zone (Faulted Zone)
Alarm Alarm Zone (Faulted Zone)
Alarm Alarm Zone (Faulted Zone)
System Disarmed Ready To Arm
System Disarmed Not Ready To Arm System Not Ready, Zones Faulted
––
––
––
System AC Loss
Low Battery
press
and
release
any
FCC ID.CFS8DL5804BDV
Speech
You must depress the button pair for at least 2 seconds for the
5804BDV to recognize the button pair command. These button
pairs allow the user to activate panic, fire, and medical alarms
depending on control panel programming.
button
A + C Button Pair
Low-Battery Indication
When the unit goes into a low battery condition, the yellow
LED will not flash when a button is pressed. Change both
batteries
Install/Replace Batteries" paragraph on first page.
Specifications
Physical:
Battery:
FCC STATEMENT
– 3 –
System Status
Armed Away or Maximum
Armed Stay or Instant
Fire Alarm in progress
Armed, Burglary Alarm in progress
Alarm Memory
Disarmed, Ready to Arm
Indicates RF transmission (Non encrypted)
Indicates RF transmission (encrypted)
In Enter House ID Mode
In Enable or Disable Encryption Mode
In Set Volume Level Mode
AC Loss Condition
Low Battery Condition
B + D Button Pair
immediately.
Refer
to
Belt Clip:
4.1H x 2.2"W x 0.8"D
Transmitter:
3.9"H x 2.0"W x 0.69"D
Maxell CR2430 or Duracell DL2430
5804BDV-005-V0
instructions