- ページ 16
ゲートオープナー Gainwise SS1806-3G-HのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Gainwise SS1806-3G-H 17 ページ。
No.
Command
28
75[N][phone number]#
75[N]*#
29
SMS confirmation of relay
30
switching
31
999#
User commands to check system info & control relay via SMS
No.
Command
*21* 1234 #
1
2
*22*1234#
3
*23*1234#
*24*1234#
4
*31*1234#
6
*32*1234#
8
*33*1234#
10
11
*71*5678 #
12
*72*5678 #
13
*73*5678#
14
*74*5678 #
15
*75*5678 #
16
*76*5678#
3G Gate Opener
Description
mobile number to receive an
SMS message when inputs are
trigged or power failure
Delete mobile number of alarm
contact when inputs are
triggered.
871+N#
Reset
Description
check 3G signal strength
and operator
Reply stored numbers
Reply alarm contact
numbers when inputs are
triggered
Check relay and inputs
status
To check input 1 SMS
content
To check input 2 SMS
content
To check input 3 SMS
content
Trigger relay 1
Hold relay 1
Release relay1
Trigger relay 2
Hold relay 2
Release relay2
16/17
settings
N=phone number 1, 2 or 3
phone number =3 ~14 digits
N=1~3(sequence of phone
number)
N= 0 or 1 0= disable
1= enable
SMS messages:
Relay 1 trigger, relay 2 trigger
Relay 1 hold, relay 2 hold
Relay 1 release, relay 2 release
SMS Reply
Signal Level = 0~31
From poor to strong
[ number1]#[number2]#[number3]#......
E:Next page / N: End
[ number1]#[number2]#[number3]#
Relay1: < status >
Relay2: < status >
Status= hold/ release/ triggered
IN1:< status>
IN2:< status>
IN3:< status>
Status= high / low
IN1: high/IN2: high/ IN3: low (standby)
IN1: low/IN2: low/ IN3: high (triggered)
Default SMS " trigger 1 is active"
Default SMS " trigger 2 is active"
Default SMS " trigger 3 is active"
Relay1 trigger
Relay1 hold
Relay1 release
Relay2 trigger
Relay2 hold
Relay2 release
Revision V1.3B, Jan 2020
Default
N/A
N/A
0