- ページ 2
キーパッド 2gig Technologies Touch Screen Wireless KeypadのPDF クイックマニュアルをオンラインで閲覧またはダウンロードできます。2gig Technologies Touch Screen Wireless Keypad 5 ページ。 Touch screen wireless keypad for remote control of the 2gig security system
SELECTING A LOCATION FOR THE KEYPAD
Make sure that AC Power is available nearby.
1
TIP:
Be careful of studs, electrical wires and pipes in the wall.
2
Use the keypad's back cover as a template to mark the screw holes
with a pencil and the power (wiring) access hole.
Use a drywall saw to cut the wiring hole.
3
Mounting the Keypad
Use the 3 screws and anchors that are supplied to attach the
1
mounting plate to the wall.
Route 18 AWG wire between the keypad and the location of the
2
power supply.
Wire Size and Length
To ensure proper operation, Do Not exceed the following maximum
length for the wire size installed:
Wire Size
Maximum Length
22 AWG
55 feet (16.8 meters)
20 AWG
85 feet (25.9 meters
22 AWG 2‐pairs
110 feet (33.5 meters)
(19 AWG equivalent)
18 AWG
135 feet (41.1 meters)
To ensure that the appropriate wire size and length are installed,
measure the voltage between the power connection terminals at the
back of the control panel. The voltage measured must not fall below 11
volts DC or nuisance "AC Power Loss" messages may be displayed and
reported.
NOTE:
In the United States, wiring routed inside walls, ceilings, and
floors must comply with requirements of the National Electrical
Code, ANSI/NFPA 70 and local building codes. For wiring from
the output of the 2GIG class II power supply, wiring rated CL2,
CL2X, CL2R, or PLTC is recommended to satisfy these
requirements. If this wiring is installed in an air plenum (space
used for environmental air exchange) it must be rated CL2P
(plenum rated).
2
©2013 2GIG Technologies Inc. All Rights Reserved.
Connect the Power Wires to the Keypad
1
Re‐connect the hanging strap.
Use #6 insulated spade terminals (not supplied) to connect wires
2
from the power supply to the keypad.
3
Close the keypad.
A Snap case closed.
B Tighten case screw.
Connect the power wires to the power supply.
4
A Left Terminal 14 VDC(+)
B Right Terminal 14 VDC (-)
C 18 AWG/2-Conductor