INSTALLATION

Installation accessories Figure 6.
1.
Fix motor support "S" shown in figure 6 on the door in the position shown in figures 2,3 or 4, depending on the mounting type.
2.
Mount the operator on this support, using the M8x16 bolts supplied.
3.
Insert part "2" of figure 6 10mm into a transmission bar O/D 28mm and weld. This bar is not supplied with the mounting kit. (It is recommended
that this bar is a pressure tube with wall thickness 4 or 5mm).
4.
Position part "U" of figure 6 as shown in figures 2,3 or 4 such that the transmission bars are completely in line with the axis of rotation of the
operator.
5.
Fix supports "L" of figure 6 as shown in figures 2,3 or 4, depending on the mounting type.
6.
Mount parts "4" of figure 6 to support "L" of figure 6 and insert parts "4" with part "3" of figure 6.
7.
Insert the transmission bars welded to part "2" in the hole of part "3" figure 6. Mount the transmission bars in the operator and fix them with parts
"U".
8.
The point marked on the rotary shaft on the right-hand side of the operator 1RM-2**37 must be as shown in figure 6, depending on the mounting
type. Before welding parts "3" to the transmission bars the operator should be rotated approximately 5 degrees away from the end position. With
the door completely closed, proceed to weld.
9.
Once the complete system is assembled, check manually that the door can be fully opened and closed.
10.
Open the upper cover (marked "1" in figure 6) which gives access to the connection terminals and connect as shown in figure 8.
11.
Adjust the pressure of the relief valves (marked "5" and "6" in figure 1) to the minimum possible so that the door dose not move with excess
force (see figure 9).
12.
If using a hydraulic lock, see figure 9.
13.
With 1RM-2RT37 operators the lever (marked "4" in figure 1) must be in position "AUT" for automatic operation and in position "MAN" for manual
operation.
Installation accessories Figure 7.
1.
Follow points 1 and 2 as above.
2.
The point marked on the rotary shaft on the right-hand side of the operator 1RM-2**37 must be as shown in figure 7. Before welding parts
"1","2","3" and "4" of figure 7 to the operator as shown in figure 7 the operator should be rotated approximately 5 degrees away from the end
position. Then fit parts "5" and "6" of figure 7.
3.
Fix part "G" of figure 7 to the door as shown in figure 5.
4.
Follow points 9 to 12 as above.

HYDRAULIC LOCK

Operator 1RM-2D37:
Connect the hydraulic lock to the hydraulic lock port (marked "C" in figure 9) for mounting types "A" or "B" and to the
hydraulic lock port (marked "D" in figure 9) for mounting type "C".
Operator 1RM-2RT37: Connect the hydraulic lock to the hydraulic lock port (marked "B" in figure 1) for mounting types "A" or "B" and to the hydraulic
lock port (marked "A" in figure 1) for mounting type "C".

MAINTENANCE

Check the oil level (marked "2" on figure 1) every 6 months.
The oil should be changed every year or every 250,000 cycles. The following oil types should be used: HLPD-32.
Every 5 years the seals should be changed.