CHANGING THE FILTERS

Disconnect power before changing filter.
CAUTION
STEP 1:
Open the front door from
the right hand side.
ACTIVEPURE
CELL REPLACEMENT INSTRUCTIONS
®
The following instructions will permit the unit's ActivePure
professional environment.
Step 1:
Always disconnect (unplug) device from electrical power source before replacing the ActivePure
Step 2: If necessary, relocate the device to an appropriate area to perform cell replacement. Do not replace
cell in areas where exposure may occur.
Step 3: Remove the 4 screws securing the old cell mounting plate on the device.
Step 4: Slide the old cell out of the device and disconnect the bulb socket.
Step 5: Open the replacement cell carton and remove the new cell.
Step 6:
Place old cell inside the empty new cell carton and dispose of properly.
NOTE:
No special handling for contaminants is necessary as the cell is on the exhaust side of the device and
does not trap or contain contaminants.
Step 7: Reattach the bulb connection to the new cell.
Step 8: Slide the new cell back inside the device and secure with the 4 screws removed in Step 3.
Step 9: Plug device in and reset the ActivePure
button for 4 ~ 5 seconds until it goes out.
Step 10: The device is now ready to be returned to its location.
REPLACEMENT PARTS & SERVICE
Use only replacement part recommended by the manufacturer.
WARNING
REPLACEMENT PARTS (QTY)
ActivePure
HEPA Filter (1)
®
ActivePure
Cell/Bulb (1)
®
To order replacement parts, contact your sales representative or ActivePure
6
STEP 2:
Remove old filter.
Cell Change Light by pressing and holding the power
®
for further assistance at 800.572.1446 or email [email protected].
STEP 3:
Clean ion chamber.
Cell to be safely replaced without creating safety concerns in your
®
Part Number
49949
50086
STEP 4:
Replace with new ActivePure
HEPA particle filter.
Cell
®
Customer Service
®
STEP 5:
Close front door.
®