- ページ 3

アクセサリー Celestron CGE800のPDF 通信プロトコル・マニュアルをオンラインで閲覧またはダウンロードできます。Celestron CGE800 8 ページ。 Schmidt-cassegrain optical tube assembly
Celestron CGE800 にも: 補足マニュアル (17 ページ), 取扱説明書 (12 ページ)

Celestron CGE800 通信プロトコル・マニュアル
Command Function
Variable rate Azm (or
RA) slew in positive
direction
Variable rate Azm (or
RA) slew in negative
direction
Variable rate Alt (or
Dec) slew in positive
direction
Variable rate Alt (or
Dec) slew in negative
direction
Fixed rate Azm (or RA)
slew in positive
direction
Fixed rate Azm (or RA)
slew in negative
direction
Fixed rate Alt (or DEC)
PC Command
"P" &
chr(3) &
chr(16) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(16) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(17) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(17) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(2) &
chr(16) &
chr(36) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
"P" &
chr(2) &
chr(16) &
chr(37) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
"P" &
Hand Control
Applies to
Response
Versions
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+