3.2. Indicating LEDs
RFID LED: one blink every 2 seconds means that the device is ready to read RFID cards.
Power supply LED. When the external feeder is connected, the power supply LED is active. When the device is fed by
the internal battery, the power supply LED is inactive. When the battery is low, the power supply LED blinks once every
2 seconds, and the device emits a single long sound every minute. In this case, you must immediately connect the
external feeder. Battery charging time: over 6 hours.
Distribution and interlock instructions: if a wrong password is entered nine times, the keyboard will be automatically
blocked, and an alarm signal will be sent to the control panel (the keyboard must be paired with the control panel). The
distribution/interlock LED blinks once every 2 seconds. During that time, the keyboard emits a continuous signal for 30
seconds. The keyboard will get blocked for 3 minutes. During that time, you cannot input any data. After 3 minutes,
normal operation is restored, and the distribution/interlock LED turns off.
3.3 Power on/off
Please note that the keyboard is off before the first use. To switch it on, simultaneously press [*] and [#] until you hear
a long sound, which indicates that the keyboard has been successfully activated. To switch the keyboard off, enter the
"setup password" and then press [#] and hold it for 3 seconds until you hear a long sound, which indicates that the
keyboard has been deactivated.
4. Operations on buttons
• Arming the alarm for an empty building: enter your password and press [
• Arming the alarm if there are people in the building: enter your password and press [
3 seconds
• Disarming: enter your password and press [
• Deleting a previously entered parameter: press [*]
• Activating an RFID card scanner: Press and hold [*] for 3 seconds
• Adding a device remotely to the existing structure. Proceed as in the alarm panel manual. Activate the remote device
addition mode in the control panel, and then enter your password and press [
signal to assign the device to the alarm panel.
• To make it possible for all programmed users to arm and disarm the alarm, just repeat this procedure using all the
pre-set user passwords.
Note
1. If the device is fed by a battery, the RFID reader scans the cards for 10 seconds. After that time, it will automatically
go to standby mode. To activate it, press and hold [*] for 3 seconds.
2. If the device is fed by the external feeder, the RFID reader works in continuous operation mode.
5. Programming
5.1. Program password
Changing the program password from default settings to user settings. Procedure.
Enter the default [program password], add [00], enter the [new password] and press [#].
The program password is used to set the keyboard's operating parameters and the access to the RFID reader settings
mode. The program password consists of 6 bits (digits).
Example new password: 012345
Keyboard set to standby mode. On the keyboard, enter the sequence of characters [88888800012345] and press [#]
to save the new parameters.
5.2 User password 1 to 8
Setting user passwords.
Procedure. Enter the [program password], enter the user number [01 to 08], enter the authorisation tag for the user [01],
enter new [user password], and confirm by pressing [#].
A password can be assigned to a maximum of eight users.
The authorisation tag is used to set user's authority to arm/disarm the alarm and has the following values:
] or press and hold [
] or press and hold [
]
]. In this way, you will send a radio
01 – user authorised to perform the operation,
00 – user not authorised to perform the operation.
The user password is required to arm/disarm the alarm. The user password consists of 4 bits (digits).
Example new user password: 1234
Keyboard set to standby mode. On the keyboard, enter the sequence of characters [88888805011234] and press [#] to save
the new parameters.
5.3 Setting the functionalities of system arming/disarming for RFID cards
Procedure. Enter the [program password], add [09], enter a tag for arming/disarming function [00 = disarming; 01 = arming;
02 = arming/disarming], and press [#].
Based on the pre-set function tag, the RFID card may only arm the alarm, only disarm the alarm, or both arm and disarm the
alarm.
Example: setting the RFID card functionality for arming the alarm only.
Keyboard set to standby mode. On the keyboard, enter the sequence of characters [8888880901] and press [#] to save the
parameters.
5.4 Adding RFID cards to keyboard memory
Procedure. Enter the [program password], add [90] and press [#].
An added card with an assigned function allows you to arm and/or disarm the alarm by moving it closer to the keyboard's
card reader.
Procedure. Keyboard set to standby mode. Enter a sequence of characters 88888890 #; at this moment the RFID indicator
] for 3 seconds
light will start blinking and the keyboard will switch to RFID card saving mode. On the keyboard, enter the number of the
] for
assigned card [1 to 8] and move the card close to the reader. If the RFID indicator light blinks, the applied card will be
assigned. If the RFID indicator light is continuously illuminated for a longer time, it means that the card is already saved in
the memory. To delete a keyboard memory record, press and hold [*] for 3 seconds. Press [#] to leave the RFID card setting
mode.
5.5 Restoring default settings
Procedure. Enter the [program password] + [99] + [#].
This will restore the keyboard default settings.
5.6 Default settings
Note: If you forget your program password, press
simultaneously [*] and [#] on the keyboard and hold
them for 15 seconds. The keyboard will be restarted. The
keyboard will emit two short sounds and restore its
default settings.
6. Technical parameters
Dimensions: 141mm x 140mm x 25mm (l×w×h)
Power supply: DC 5V, 1A
Battery: 3.7V / 800mAh
Power consumption at standby: ≤60uA
Power consumption during operation: ≤50mA
Battery operation time at standby: approx. 1 year (with
battery fully charged)
Alarm noise level: ≤ 70dB
Communication frequency: 433.92MHz
Wireless signal range: ≤250m (in open space)
Work environment:
Operating temperature: -20°C ~ +55°C Humidity: 40 ~ 80%