- ページ 3
バッテリーチャージャー Cell-Con 452240-S SeriesのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Cell-Con 452240-S Series 3 ページ。 Lead acid
Explosive gases can arise while charging. Avoid sparks and open flames. Verify
that there is adequate ventilation while charging. The charger should not be used
in the vicinity of flammable anesthesia gases. Avoid chargers with plastic casing
coming into contact with oils, grease, etc., as most types of plastic can be broken
down by chemicals and solvents.
LED's INDICATE FOLLOWING CHARGE STATUS
Fast charge
The charger is in constant current mode.
Charge current is at its maximum.
Final charge
The charger is in constant voltage mode.
Charge current is less than its maximum.
The battery is normally 80-95% charged.
The charger stays in this mode until the charge current
decreases to charge termination level.
Float (Standby / Ready)
The charger is in standby mode.
The battery is fully charged. The LED changes to green.
The charge voltage is at standby level, which means the charger
can continue to be connected to the battery.
The charger can return to rapid charging if the battery is used.
Charging diagram
WARNING
RED
RED
Red
Red