- ページ 3
扇風機 AIRE DECOR BP215-1 SeriesのPDF 取付説明書をオンラインで閲覧またはダウンロードできます。AIRE DECOR BP215-1 Series 8 ページ。
4. MOUNTING OPTIONS
If there isn't an existing UL listed mounting box,
then read the following instructions. Disconnect the
power by removing fuses or turning off circuit
breakers.
Secure the outlet box directly to the building
structure. Use appropriate fasteners and building
materials. The outlet box and its support must be
able to fully support the moving weight of the fan
(at least 50 lbs). Do not use plastic outlet boxes.
Figures 1,2 and 3 are examples of different ways to
mount the outlet box.
Note: You may need a longer downrod to maintain
proper blade clearance when installing on a steep,
sloped ceiling. (Fig. 3)
To hang your fan where there is an existing fixture
but no ceiling joist, you may need an installation
hanger bar as shown in Figure 4.
Outlet box
Figure 1
Outlet box
Figure 2
Angled ceiling
Provide strong
maximum 25 º
support
Recessed
outlet box
Ceiling
mounting
bracket
Figure 3
Outlet box
Figure 4
3
5. HANGING THE FAN
REMEMBER to turn off the power. Follow the steps
below to hang your fan properly. NOTE: This ceiling
fan is supplied with two types of hanging
assemblies; the standard ceiling installation using
the downrod with ball and socket mounting and the
"close-to-ceiling" installation. The "close-to-ceiling"
installation is recommended in rooms with less than
8-feet ceilings or in areas where additional space is
desired from the floor to the fan blades.
STANDARD CEILING INSTALLATION
Step 1. Pass the 120-volt supply wires through the
center hole in the ceiling hanger bracket as shown in
Fig. 5.
Step 2. Secure the hanger bracket to the ceiling
outlet box with the screws and washers provided
with your outlet box.
Step 3. Remove hanger ball from downrod
assembly by loosening set screws, removing the
cross pin, and sliding ball off rod. (Fig. 6)
Step 4. Loosen the two set screws and remove the
hitch pin and lock pin from the top coupling of the
motor assembly. (Fig. 7)
Step 5. Carefully feed the fan wires up through the
downrod. Thread the downrod into the coupling until
the Hitch pin holes are aligned. Next, replace the
lock clip and hitch pin then tighten the set screws.
(Fig. 7)
UL Listed
electrial
box
Ceiling
mounting
plate
Hook
Mounting screws
(supplied with
electrical box)
120V Wires
Figure 5
Cross pin
Hanger
ball
Set screw
Downrod
Figure 6
Supply wires
Downrod
Set screws
Lock pin
Set screws
Figure 7
4
Washers
Hitch pin