Output Mode

Output mode is available to set. (Indicator does not support output mode.)
ON:
OFF:
■ S (Standard) output mode
• Comparative value setting condition:
individual output operation regardless of
size or order of set comparative values
HH output:
Display value
≥ Comparative value HH
H output:
Display value
≥ Comparative value H
L output:
Display value
≤ Comparative value L
LL output:
Display value
≤ Comparative value LL
GO output:
No HH, H, L, LL output
HH
H
L
LL
HH
H
H
H
GO
L
H
LL
H
■ L (Low) output mode
• Comparative value setting condition:
individual output operation regardless of
size or order of set comparative values
HH output:
Display value
≤ Comparative value HH
H output:
Display value
≤ Comparative value H
L output:
Display value
≤ Comparative value L
LL output:
Display value
≤ Comparative value LL
GO output:
No HH, H, L, LL output
HH
H
L
LL
HH
H
H
H
L
H
LL
H
GO
■ I (One-shot) output mode
• Comparative value setting condition:
individual output operation regardless of
size or order of set comparative values
• One-shot output time: 0.3 sec (fixed)
• No GO output.
• No hysteresis.
HH output: Display value
Comparative value HH
H output:
Comparative value HH > Display value ≥
Comparative value H
L output:
Comparative value H > Display value ≥
Comparative value L
LL output: Comparative value L > Display value ≥
Comparative value LL
HH
H
L
LL
HH
0.3s
H
GO
0.3s
L
0.3s
LL
H: hysteresis
■ H (High) output mode
• Comparative value setting condition:
individual output operation regardless of
size or order of set comparative values
HH output:
Display value
≥ Comparative value HH
H output:
Display value
≥ Comparative value H
L output:
Display value
≥ Comparative value L
LL output:
Display value
≥ Comparative value LL
GO output:
No HH, H, L, LL output
HH
H
L
LL
HH
H
H
L
H
LL
H
GO
■ B (Block) output mode
• Comparative value setting condition:
LL<L<H<HH
HH output: Display value
Comparative value HH
H output:
Comparative value HH > Display value ≥
Comparative value H
L output:
Comparative value LL < Display value ≤
Comparative value L
LL output: Display value
Comparative value LL
GO output: No HH, H, L, LL output
HH
H
L
LL
HH
H
H
GO
L
H
LL
H
■ F (Deflection) output mode
• Transmits outputs when the saved
setting value exceeds H deviation or L
deviation.
• Comparative value setting
: Based on the set value, set the H / L
deviation in the P0-2, P2-7 H
comparative value and P0-3, P2-8 L
comparative value parameters.
( The set deviation value is saved during
Power OFF until it is re-set.)
• Comparative value setting range
: 0.0001 to 99999
The setting range is different according
to the P2-2 Decimal point position of
0.3s
display value setting.
E.g.) In case of P2-2 Decimal point
position of display value = 0000.0,
setting range = 0.1 to 9999.9
• Saving setting value: [MODE] + [▲]
• Checking setting value: [▲]
• No HH, GO, LL output.
• The deviation can be set to "0" but the
actual operation will be the same as "1".
Save SV
(Max.)H deviation
SV
(Min.) L deviation
Power
Save SV
01)
L deviation
output
02)
H deviation
output
01) When P1-6 Delay monitoring = F.DEFY is set, there is
no output.
02) The graph is assuming that there is a saved setting
value prior to the setting value save point. The actual
output position may be different.

Operation Mode

■ F1: frequency / revolutions / speed
Measures the frequency of input A and displays the calculated frequency, revolutions,
and speed.
Frequency (Hz)
Revolutions (rpm) = f × α
Speed (m / min)
Display value
Display unit
Hz
Frequency
kHz
rps
Revolutions
rpm (default)
mm / sec
cm / sec
Speed
m / sec
H
m / min
km / hour
Input A
t1
t2
Hold
Display
1
× α
t1
■ F2: passing speed
Displays the passing speed between input A ON and input B ON.
Passing speed (V)
Display value
Display unit
mm / sec
cm / sec
Passing speed
m / sec (default) 1 L
m / min
H
km / hour
Input A
Input B
Hold
ta
t1
t2
1
Display
× α
t1
• ta: Return time (≥ 20 ms)
■ F3: cycle
Displays the measured time from input A ON to the next ON.
Cycle (T)
= t
Display value
Display unit
SEC
999.99 s
(default)
9999.9 s
Cycle
99 m 59.9 s
9 h 59 m 59 s
99999 s
Input A
t1
Hold
Display
■ F4: passing time
Measure the time from input A ON to the next ON, and displays the passing time of the
arbitrary distance.
Passing time [sec]
(α=
Distance advanced in 1 pulse cycle [m]
Display value
Display unit
SEC
999.99 s
(default)
9999.9 s
Passing time
99 m 59.9 s
9 h 59 m 59 s
99999 s
Input A
t1
Hold
t1 × α t2 × α
Display
• L: travel distance of conveyor belt of 1
= f × α
(α = 1 [sec])
cycle [m]
(α = 60 [sec])
• α: prescale value
= f × α
(α = 60 L [sec])
(For multiple objects, α = 60L / N)
α
1
0.001
1
MP5
60
1,000 L
100 L
1 L
60 L
3.6 L
t3
t4
t5
t6
1
1
1
1
× α
× α
× α
× α
t2
t3
t5
t6
• f : reciprocal of time [sec] between input A
= f × α
(α = L [m])
(sensor) ON and input B( sensor) ON.
• L: distance between input A (sensor) and
α
input B (sensor) [m]
1,000 L
• α: prescale value
100 L
60 L
3.6 L
Sensor B
t3
t4
t5
t6
t7
1
1
1
1
1
× α
× α
× α
× α
× α
t2
t3
t4
t6
t7
• t: measurement time [sec]
MIN
999.99 m
9999.9 m
99 h 59.9 m
Photoelectric
999 h 59 m
sensor
99999 m
t2
t3
t4
t5
t6
t3
t5
t6
t1
t2
• t: measurement time [sec]
= t × α
• L: arbitrary distance [m]
L [m]
• α: prescale value
)
MIN
999.99 m
9999.9 m
99 h 59.9 m
999 h 59 m
99999 m
t2
t3
t4
t5
t6
t3 × α
t5 × α
t6 × α
Encoder
MP5
MP5
Sensor A
MP5
MP5