計測機器 Autonics MT4N-DV SeriesのPDF 製品マニュアルをオンラインで閲覧またはダウンロードできます。Autonics MT4N-DV Series 6 ページ。 4-digit multi panel meters

Autonics MT4N-DV Series 製品マニュアル

Specifications

Model
MT4N-DV-□□ MT4N-DA-□□ MT4N-AV-□□
Input type
DC voltage
Max. allowable input 110 % F.S. for each measured input range
Display method
7-segment (red) LCD (character height: 9 mm)
Display accuracy
Dependent on the ambient temperature
23 ± 5 ℃
± 0.1 % F.S. rdg ± 2 digit
-10 to 50 ℃
± 0.5 % F.S. rdg ± 3 digit
Max. display range
-1999 to 9999 (4 digit)
A / D conversion
Practical oversampling using successive approximation ADC
method
Sampling cycle
50 ms
Unit weight
≈ 64 g (≈ 127 g)
(packaged)
Approval
ᜢ ᜫ
01) Available frequency display
02)  5 A terminal: ± 0.3 % F.S. rdg ± 3 digit
None (indicator) / Relay / NPN open collector / PNP open collector
Preset output
output model
Contact capacity: 125 VACᜠ 0.3 A, 30 VDCᜡ 1 A
Relay
Contact composition: N.O (1a)
NPN / PNP
Output capacity: ≤ 12 - 24 VDCᜡ ± 2 VDCᜡ, 50 mA resistive load
open collector
None (indicator) / Transmission (DC 4 - 20 mA) / RS485
Sub output
communication output model
Transmission
Resolution: 1/12,000 (load resistance: ≤ 600 Ω)
(DC 4 - 20 mA)
Response time: ≤ 450 ms
RS485 communication
Protocol: Modbus RTU
12 - 24 VDCᜡ ± 10 %, 12 - 24 VACᜠ ± 10 % 50 / 60 Hz /
Power supply
100 - 240 VACᜠ ± 10 % 50 / 60 Hz model
Power consumption
3 W / 5 VA
01)
(DC / AC voltage)
Power consumption
5 VA
(AC voltage)
Insulation resistance
≥ 20 MΩ (500 VDCᜡ megger)
Dielectric strength
Between external terminal and case: 1,000 VACᜠ 50 / 60 Hz for 1 min
(DC / AC voltage)
Dielectric strength
Between external terminal and case: 2,000 VACᜠ 50 / 60 Hz for 1 min
(AC voltage)
Noise immunity
± 2 kV square wave noise (pulse width: 1 ㎲) by the noise simulator
0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in
Vibration
each X, Y, Z direction for 2 hours
Vibration
0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in
(malfunction)
each X, Y, Z direction for 10 min
Shock
300 m/s
(≈ 30 G) in each X, Y, Z direction for 3 times
2
Shock (malfunction)
100 m/s
(≈ 10 G) in each X, Y, Z direction for 3 times
2
Ambient temp.
-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humi.
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Symbol:
, double or reinforced insulation (dielectric strength between
Insulation type
the measurement input part and the power part: 1 kV)
01)  Except MT4N-□□-E5: 5 W / 8 VA

Communication Interface

■ RS485
Comm. protocol
Modbus RTU
Application standard
Compliance with EIA RS485
Max. connection
31-unit (address: 01 to 99)
Comm. synchronous method Asynchronous
Comm. method
2-wire half duplex
Comm. distance
≤ 800 m
Comm. speed
1,200 / 2,400 / 4,800 / 9,600 / 19,200 / 38,400 bps
Start bit
1-bit (fixed)
Data bit
8-bit (fixed)
Parity bit
None, Even, Odd
Stop bit
1-bit, 2-bit
EEPROM life cycle
≈ 1,000,000 operations (Erase / Write)
MT4N-AA-□□
DC current
AC voltage
AC current
01)
± 0.3 % F.S. rdg ± 3 digit
02)
16.6 ms

Mode Setting

[MODE] 3 sec
01)
[MODE] 5 sec
RUN
[MODE]
[◀] + [▲] 3 sec
[◀] + [▲] + [▼] 5 sec

Parameter Setting

• Some parameters are activated / deactivated depending on the model or setting of
other parameters. Refer to the description of each parameter.
• If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
• After returning to RUN mode, press the [MODE] key within 2 sec, it returns to
previous parameter.
• [MODE] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲], [▼] key: Changes setting values.
■ Parameter 1 group
Parameter
Mark
1-1
Input range
IN-R
Display
1-2
method
DISP
Measurement
1-3
method
IN-T
Max. display
1-4
value
STND
(fixed)
High-limit
display value
1-5
gradient
INbH
correction
Low-limit
display value
1-6
deviation
INbL
correction
Decimal
1-7
point
DOT
position
1-8
High-limit scale H-SC -
1-9
Low-limit scale L-SC -
1-10 Display unit
dUNT
High-limit
display value
1-11
gradient
INbH
correction
Low-limit
display value
1-12
deviation
INbL
correction
02)
Decimal point
1-13
position
03)
DOT
High-limit
display value
1-14
gradient
INbH
correction
1-15 Exponent of INB INbE
01)  Displays at AC voltage or AC current model only.
02)  Low-limit display value deviation correction range is within -99 to 99 for D
03)  Display range is variable according to decimal point position.
Dot
Display range
-1999 to 9999
0
-199.9 to 999.9
)0
-19.99 to 99.99
)00
-1.999 to 9.999
)000
Parameter 1
[MODE] 3 sec
group
Parameter 2
[MODE] 3 sec
group
Parameter 0
[MODE] 3 sec
group
Auto
Zero adjustment
Reset
[MODE]
Defaults Setting range
[DC voltage model]
• Refer to Input Range and Display Range
50
[DC current model]
• Refer to Input Range and Display Range
500
[AC voltage model]
• Refer to Input Range and Display Range
250
[AC current model]
• Refer to Input Range and Display Range
5
STND: standard, SCAL: scale, FREQ:
frequency
01)
STND
[AC voltage model], [AC current model]
T.RMS: True RMS, A.RMS: Average RMS,
AVG
A
+ A
+ ··· + A
2
2
• True RMS =
1
2
n
A
+ A
+ ··· + A
tRMS
• Average RMS =
1
2
n
× Waveform rate
(n = number of display values per cycle,
A = display value)
[DC voltage model]
Max. value of display range
5)00
[DC current model]
Max. value of display range
50)0
[AC voltage model]
Max. value of display range
25)0
[AC current model]
Max. value of display range
%000
!000 0.100 to 5.000 %
00 -99 to 99
)00 [DC voltage model] 0, 0.0, 0.00, 0.000
[DC current model], [AC voltage model]
0, 0.0, 0.00, 0.000
)0
)000 [AC current model] 0, 0.0, 0.00, 0.000
Display value against max. measurement input*
Display value against min. measurement input*
[DC voltage model], [AC voltage model]
MV, V, OFF
V
[DC current model], [AC current model]
MA, A, HZ, OFF
A
!000 0.100 to 5.000 %
00 -99 to 99
)0 [AC voltage model] 0, 0.0, 0.00, 0.000
)000 [AC current model] 0, 0.0, 0.00, 0.000
!000 0.100 to 9.999
10-0 10-0: 10
, 10-1: 10
, 10-2: 10
0
-1
, D
digit regardless of decimal point position.
0
-1
Frequency measurement range
1 to 9999 Hz
0.1 to 999.9 Hz
0.10 to 99.99 Hz
0.100 to 9.999 Hz
RUN
Display
condition
-
-
-
-
-
1-2
2
Display
n
method:
STND,
n
SCAL
1-2
Display
method:
STND
1-2
Display
method:
SCAL
&
* 1-7
Decimal
point
position:
0.0, 0.00,
0.000
1-2
Display
method:
FREQ
, 10 1: 10
-2
1