4. Install the spark plug finger tight in the cylinder head
then tighten it firmly with the spark plug wrench.
Air filter
The air filter should be checked approximately every
10 hours of use, or more frequently in dusty areas.
1. Unclip the filter cover on
the side, hinge around and
remove the cover and
filter element.
2. Inspect the element. If
the element is distorted or
damaged, replace it with a
new one.
3. Wash the filter in detergent
and water. Rinse the filter
thoroughly. Squeeze out
excess water. Allow it to dry
completely before reinstalling.
4. Install the element and cover
and then replace the cover
and clip into place.
Servicing
It is recommended once you first use your petrol blower
have it serviced after 15 hours of use.
Thereafter, service the petrol blower every 2 years.

Storage and maintenance after use

When you finish working, clean the petrol blower completely.
Inspect the entire blower and tubes for damage,
including loose or missing components, and repair
anything necessary.
Store the petrol blower away from direct sunlight.
Do not store in a nylon bag as this can encourage the
formation of mould.
Use a small brush to clean off the outside of the unit
and keep the air vents free from obstructions. Do not
use water or a hose to clean the unit.
Whenever the machine is not used for a long period of time,
proceed as follows:
Give the petrol blower an overall cleaning and a
thorough check.
Empty the fuel tank completely, then clean the
carburettor and lines by running the blower until it
stops from lack of fuel.
Protect all metal engine parts from corrosion by coating
them with oil.
Remove the spark plug, put several drops of oil into the
cylinder through the spark plug hole and then pull the
recoil starter 2 to 3 times in order to distribute the oil
evenly. Replace the spark plug and spark plug cover.
Clean the air filter as described in the air filter section.