- ページ 2
タイマー Autonics FS SeriesのPDF 製品マニュアルをオンラインで閲覧またはダウンロードできます。Autonics FS Series 4 ページ。 8-pin plug digital counters
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
FS
❶
-
❷
❸
❶ Display digits
4: 4-digit
5: 5-digit
❷ Output
1P: 1-stage setting (4-digit)
I: Indicator (5-digit)
Product Components
• Product (+ bracket)
Sold Separately
• 8-pin socket: PG-08, PS-08(N)
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
12.3
63.8
□48
10.5
■ Bracket
□49.5
30.5
60.3
Connections
■ FS4-1P4
12 VDCᜡ 50 mA
PNP
COUNT IN
CONTACT:
RESET
250 VACᜠ 3 A,
30 VDCᜡ 3 A
0 VDCᜡ
NPN
RESISTIVE
LOAD
SOURCE:
100 - 240 VACᜠ 50 / 60 Hz 4.6 VA
■ FS5-I4
12 VDCᜡ 50 mA
PNP
COUNT IN
RESET
NPN
0 VDCᜡ
SOURCE:
100 - 240 VACᜠ 50 / 60 Hz 3.8 VA
Error
• When error occurs, the output turns OFF.
• Indicator model does not have error display function.
Display
Description
Troubleshooting
Setting value = 0
Change the setting value anything but 0.
ERR0
❸ Power supply
2: 24 VACᜠ ± 10 % 50 / 60 Hz,
24 - 48 VDCᜡ ± 10 %
4: 100 - 240 VACᜠ ± 10 % 50 / 60 Hz
• Instruction manual
14
■ Panel cut-out
≥ 65
■ FS4-1P2
12 VDCᜡ 50 mA
PNP
COUNT IN
CONTACT:
RESET
250 VACᜠ 3 A,
30 VDCᜡ 3 A
NPN
0 VDCᜡ
RESISTIVE
LOAD
SOURCE:
24 VACᜠ 50 / 60 Hz 3.5 VA
24 - 48 VDCᜡ 2.3 W
Specifications
Model
FS4-1P□
Display digits
4-digit
Character size
W 3.8 × H 7.6 mm
Max. counting speed
1 / 30 / 2 k / 5 k cps
Return time
≤ 500 ms
Min. signal width
RESET: ≈ 20 ms
Voltage input (PNP) - input impedance: ≤ 10.8 kΩ,
Input logic
No-voltage input (NPN) - short-circuit impedance: ≤ 470 Ω,
One-shot output time
0.05 to 5 sec
Contact control output
Relay
Type
Instantaneous SPST (1a) × 1
250 VACᜠ 3 A, 30 VDCᜡ 3 A
Capacity
resistive load
Unit weight (packaged) ≈ 90 g (≈ 130 g)
Approval
ᜢ ᜧ ᜫ
Voltage type
AC voltage
Power supply
100 - 240 VACᜠ ± 10 % 50 / 60 Hz
Power consumption
≤ 4.6 VA
(FS4-1P□)
Power consumption
≤ 3.8 VA
(FS5-I4)
External supply power
≤ 12 VDCᜡ ± 10 % 50 mA
Memory retention
≈ 10 years (non-volatile semiconductor memory type)
Insulation resistance
≥ 100 MΩ (500 VDCᜡ megger)
Dielectric strength
Between all terminals and case: 2,000 VACᜠ 50 / 60 Hz for 1 minute
± 2 kV square wave noise (pulse
Noise immunity
width: 1 ㎲) by the noise simulator
0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1 minute)
Vibration
in each X, Y, Z direction for 1 hour
0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 minute) in
Vibration (malfunction)
each X, Y, Z direction for 10 min
Shock
300 m/s
(≈ 30 G) in each X, Y, Z direction for 3 times
2
Shock (malfunction)
100 m/s
(≈ 10 G) in each X, Y, Z direction for 3 times
2
Mechanical: ≥ 5,000,000 operations
Relay life cycle
Electrical: ≥ 100,000 operations (250 VACᜠ 3 A resistive load)
Ambient temperature
-10 to 55 ℃, storage: -25 to 65 ℃ (no freezing or condensation)
Ambient humidity
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Protection rating
IP20 (front part, IEC standard)
Mode Setting
RUN
→
Decimal Point Setting
[RESET] 3 sec
Decimal Point Setting
• If there is no RESET key or DIP switch input for 60 sec, it returns to RUN mode.
• [RESET] key: Setting mode ↔ RUN mode
Move the digit when changing the setting value.
Parameter
Display
C1-1 Setting mode
DP
Decimal point
----
C1-2
setting
-----
Output Operation Mode
For the detailed timing chart for operation output mode, refer to the manual.
FS5-I4
5-digit
W 4 × H 8 mm
[H]: 5 - 30 VDCᜡ, [L]: 0 - 2 VDCᜡ
short-circuit residual voltage: ≤ 1 VDCᜡ
open-circuit impedance: ≥ 100 kΩ
-
-
-
≈ 80 g (≈ 120 g)
AC / DC voltage
24 VACᜠ ± 10 % 50 / 60 Hz,
24 - 48 VDCᜡ ± 10 %
AC: ≤ 3.5 VA
DC: ≤ 2.3 W
-
± 500 V square wave noise (pulse
width: 1 ㎲) by the noise simulator
[RESET] 3 sec
Setting range
-
[FS4-1P□]
----, ---.-, --.--, -.---
[FS5-I4]
-----, ----.-, ---.--, --.---, -.----
→ RUN