Proper usage
Reset function
● Reset
In case of changing the input mode after supplying the
power, please take external reset or manual reset.
If reset is not executed, the counter will be working
as previous mode.
● Reset signal width
It is reset perfectly when the reset signal is applied during
min. 20ms regardless of the contact input & solid-state
input.
*
Reset input
* In case of a contact reset, it is reset perfectly if the ON
time of reset signal is applied during min.
20ms even though a chattering is occurred.
** It can be input the signal of CP1, CP2 after min.
50ms from closing time of reset signal.
Sensor power
The power 12VDC which is provided to sensor is built in it.
Please use it under Max. 50mADC.
Min. signal width
*T
1
1
**
**
* Please make duty ratio(ON/OFF ) 1:1
1cps : Min. 500ms
30cps : Min. 16.7ms
** Min. signal width
2kcps : Min. 0.25ms
5kcps : Min. 0.1ms
Max. counting speed
This is a response speed per 1 sec. when the duty ratio
(ON:OFF) of input signal is 1:1.
If the duty ratio is not 1:1, the width between ON and OFF
should be over min. signal width and the response speed
will getting slower against input signal. And one of ON width
and OFF width is under min.signal width, this product may
not respond.
Ta Tb
Width of Ta(ON)and Tb(OFF)
must be larger than Min. signal
width.
Max. counting speed is 1/2 value
3×Ta
of rated spec. when duty ratio
is 1:3.
It can not respond if it is smaller
than min. singal width(Ta).
Up/Down Counter/Timer
INHIBIT(For timer)
● If SW1 is ON, it becomes INHIBIT. (Time Hold)
● When power is applied, it starts to progress and
INHIBIT mode is used to stop the time is under
the progress at the moment.
● When SW1 is OFF, timer starts to progress again.
**
Error display
Error signal
※ When Error is displayed, the output continues OFF state.
※ There is no Error function in indicator.
Power
The inner circuit voltage starts to rise up for the fi rst 100ms
after power on, the input may not work at this time. And also
the inner circuit voltage drops down for the last 500ms after
power off, the input may not work at this time.
Power
Case & DIP switch detachment
Push a lock part to front direction and widen it
simultaneously.
※ Please be careful of the injury caused by tools.
(INHIBIT)
(Note1)(Note2)
SW1
6
7
8
9
10
CP1 CP2 +12V 0V
INHIBIT
Setting value
Time display value
0
(Up mode)
Error description
Returning method
Change the setting
Zero setting status
value to non zero status
ON
OFF
100㎳
The unstable time
against the input signal
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
※ (Note1): PNP input
Door/Area
sensor
(Note2): NPN input
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
power
supply
(Q)
Stepping
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
500㎳
Field
network
device
(T)
Software
(U)
Other
J-49