- ページ 2

タイマー Autonics LE4SAのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Autonics LE4SA 17 ページ。 Din w48xh48mm digital backlight lcd timer
Autonics LE4SA にも: インストラクション (18 ページ)

Autonics LE4SA マニュアル
LE4S Series

Specifications

Model
LE4S
Repeat error
SET error
Max. ±0.01% ±0.05 sec (for Power ON Start)
Max. ±0.005% ±0.03 sec (for Signal ON Start)
Voltage error
Temperature error
Insulation resistance
Over 100MΩ (at 500VDC megger)
Dielectric strength
2,000VAC 50/60Hz for 1 min
Noise immunity
±2kV the square wave noise (pulse width: 1㎲) by the noise simulator
Mechanical
0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1hour
Vibration
Malfunction
0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
Mechanical
300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Shock
Malfunction
100m/s² (approx. 10G) in each X, Y, Z direction for 3 times
Approval
ᜢ ᜧ
Unit weight
Approx. 98g
Dimensions
52
48
Bracket
36
44.9
N-24
6
56
2
Panel cut-out
LE4SA
Max. ±0.01% ±0.05 sec
14
Min. 65