Specifications
Model
LSE-4A5R2
Emitting property
Infrared laser
Laser class
CLASS 1
Wave length band
905 nm
Max. pulse output power
75 W
Response time
Typ. 20 to 80 ms + monitoring time
Scanning mode
Motion and presence
Monitoring zone
0.3 × 0.3 m to 5.6 × 5.6 m
Front contamination
Normal operation with max. 30 % contamination of one material
Min. size of the scanning
At detection distance of 3 m: ≈ W 2.1 × H 2.1 × L 2.1 cm
target
At detection distance of 5 m: ≈ W 3.5 × H 3.5 × L 3.5 cm
02)
Angular resolution
0.4°
Aperture angle
90°
Object reflectivity
≳ 2 %
Laser scanner angle
-45°, 0°, 45°
Bracket rotation angle
-5 to 5°
03)
Bracket tilt angle
-3 to 3°
Life expectancy
≲ 6.8 years
Approval
ᜢ ᜣ
Korean Railway
KRS SG 0068
Standards
Unit weight (package)
≈ 0.58 kg (≈ 0.96 kg)
01) At object reflectivity: 10 %
02) At object reflectivity: 90 % (Kodak Gray card R-27, White)
03) Indicates the laser scanner adjustment range.
Power supply
24 VDCᜡ ± 20 %
Power consumption
≤ 8 W
Communication interface
Ethernet (TCP/IP) 10BASE-T
Photocoupler input
Input
H
: ≥ 8 - 30 VDCᜡ, L: ≤ 3 VDCᜡ
01)
PhotoMOS relay output
Galvanic isolation, non-polarity
Output
Resistive load: 30 VDCᜡ / 24 VACᜠ, ≤ 80 mA
Output resistance: 30 Ω
Switching time: t
Insulation resistance
≥ 5 MΩ (500 VDCᜡ megger)
Dieletric strength
500 VACᜠ 50 / 60 Hz for 1 minute
Vibration
≤ 2 G (18.7 m/s
Shock
30 G / 18 ms
Ambient illuminance
Sunlight: ≤ 100,000 lx
Ambient temperature
-30 to 60 ℃ (no freezing or condensation)
02)
Ambient humidity
0 to 95 %RH, storage: 0 to 95 %RH (no freezing or condensation)
Protection structure
IP67 (IEC standard)
Power, I / O cable: Ø 5 mm, 8-wire, 5 m
Cable spec.
Ethernet cable: Ø 5 mm, 4-wire, 3 m, shield cable, RJ45 connector
Wire spec.
AWG26 (0.16 mm, 7-core), insulator outer diameter: Ø 1 mm
Material
PC
01) Operates as output test mode and outputs obstacle detection output and error status output.
02) Ambient temperature in power supplied status is -30 to 60℃ and in power cut status is -10 to 60℃.
Control Input / Output Status
Output
OUT1
Input
(obstacle detection output)
ON
ON
-
• Obstacle detection
• Teaching
ON
• Error status
OFF
• Scanning ready
• Obstacle non-detection
OFF
01)
= 5 ms, t
= 5 ms
ON
OFF
)
2
OUT2
(error status output)
ON
-
ON
• Error status
• Scanning ready
• Normal status
OFF
Indicators
Indicators
(green)
(green)
Ethernet
Function
Power
connection
• The operation of indicator not stated in the description is unrelated with the status.
■ Indicator by situation
Indicator
Status
Comm. cable
ON
-
connection
1 -
OFF
Scanning
2 -
OFF
waiting
3 -
OFF
sequence
4 -
OFF
Flashing
Scanning
-
(every 1 sec)
Obstacle
Flashing
-
detection
(every 1 sec)
Flashing
Teaching
-
(every 1 sec,
for 35 sec)
Output test
Flashing
-
mode
(every 0.05 sec)
■ Error indicator
Indicator
Status
1 -
Voltage error
2 -
01)
3 -
1 -
Temperature
2 -
error
01)
3 -
01) Repeat 1 to 3 step.
■ Remote control input key waiting
Indicator
Status
Password
-
OFF
Menu
-
OFF
Number
-
OFF
(green)
(red)
(orange)
Remote
control
Operation
Error
operation
-
-
-
ON
ON
ON
Flashing (twice in every 0.5 sec)
OFF
-
OFF
OFF
ON
OFF
Flashing
OFF
(every 1 sec,
OFF
for 35 sec)
OFF
-
OFF
Flahing
(3 times in every 0.2 sec)
Flashing
(1 time in every 1 sec)
OFF (2 sec)
Flashing
(1 time in every 0.2 sec)
Flashing
(3 times in every 1 sec)
OFF (2 sec)
Flashing
OFF
OFF
(every 0.05 sec)
Flashing
OFF
OFF
(every 0.3 sec)
Flashing
OFF
OFF
(every 0.05 sec)