- ページ 9

顕微鏡 Ihara VT300のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Ihara VT300 16 ページ。 Digital portable microscope

(A) Refer to section 1.5.5 to connect to computer.
(B) To operate by the device, please access "PC cam" and press "confirm".
(C) Start the application in the computer as introduced in section 2.2.
(D) Click "connect" on the application as shown in section 3.4.
(7) Set Up
: a model to set the system and provides seven functions for selection according to your own orientation. Please refer to the
following setting image. Press buttons of
image of system setting model after confirmation. Press button
(A) Date/Time
: Setup Date and Time on the device.
(B) Timestamp
: To decide to save Date/Time on the bottom left of the image. Please note that the scale on the image will not show
if this function is activate. If want to show the Timestamp on the image, please turn off the scale function.
(C) Auto Power Off
: This function can help you shut off the machine after a selected period of inactivity. Or to choose "never" to
skip this function.
(D) White balance
: set white balance automatically for switching on and off. Automatic white balance can correct image's contrast
and color. We suggest you switch on automatic white balance to achieve optimum result.
(E) Status display
: Use the button to display the status. The user can view status icons on the upper position for an image.
(F) Factory default
: Revert to factory default settings.
(G) Delete DSC/VID
(8) About
: the model to check relevant information of the product. Press button
(9) Date:(YYYY-MM-DD) :Display the system date.
(10)
Time:(HH:MM:SS) :Display the system time.
1.5 External Interfaces of Microscope
The machine contains many external interfaces. The following contents give instructions about assembly of the accessories. Please use
accessories provided together with the machine including transmission line, battery, etc. Please do not use other accessories, as this may
cause severe damage or incompatible to the machine.
(1) Connect USB Cable: The smaller connector end is used to connect with the machine, the larger connector end is used to connect USB
port on PC. While connecting to computer, power source can also be provided besides transmitting images (PC Camera). Please refer
to the following image for the USB connection.
(2) USB Power Supply: provide power supply for the machine by USB cable and USB power supply. Smaller joint is applied to connect
microscope host, and the larger one is applied to connect USB power supply (or USB connection port connecting to computer can also
provide power supply). The installation is as follows.
,
,
and
: delete VID and files in DSC folder. VID is for storing videos, and DSC is for storing photos.
to select and adjust and
(Confirmation button) to quit the model.
(Confirmation button) to quit the model.
to confirm the setting. System will be back to the