our investigation show that there is always a residual error due to the fact
that real magnetic objects do not behave exactly according to the model
outlined. Autonnic is aware that the need for a constant angular velocity
is onerous but the benefit is that it provides a very low residual error –
less than 0.5°.
Note that the calibration is different if the unit is mounted upside-down.
Calibration must always be done with the unit in its final mounted
position. The essential point of the calibration is remove the influence of
external magnetic components in the vicinity – the nearby pieces of iron
and steel –so it is essential that these remain unchanged after calibration.
If any significant iron component is altered – such as the installation of
new equipment or replacement of equipment such as winches or engines
– then the calibration must be re-done.
4.3
Terminating a bad calibration
If the process is faulty in any way – such as would happen if the
manoeuvre cannot be completed, the process can be terminated by the
NMEA command (see 5.2.17) and the original factory default (linear) table
is restored. Alternatively, this can be done by pressing both Switches
together for at least 1 second.
NOTE that there should be a delay of at least 5 seconds after termination
before a new calibration process is initiated.
4.4
Setting reference NORTH heading
Switch 2 (and also a NMEA command) is provided to set 'zero'. The
compass should
a.
first be auto-calibrated
b.
then be aligned to North
11 of 19
A5023/24