COOLING SYSTEM VACUUM PURGE AND REFILL KIT
1. FEATURES
Coolant is easily refilled by creating a vacuum in the radiator.
Eliminate airlocks during coolant refilling.
Checks for leaks and refills in seconds.
Provided with a universal adapter with 3 rubber rings:
35mm︱ 39.5mm ︱ 44mm
Adapter rings expand ca. 4mm when turning the rotor on adapter.
2. PRECAUTIONS
Always read completely the instruction manual before working.
Never use the tool in the areas that it is not designed for.
Always wear eye protection that meets OSHA and ANSI Z87.1 standards.
CAUTION
Always wear hand gloves when working with the tool.
Ensure the work area has adequate lighting.
Keep children and unauthorized persons away from the work area.
Keep work area clean and tidy and free from unrelated materials.
DO NOT allow untrained persons to use the kit.

3. SPECIFICATIONS

Main body with a gauge (-1-0 Bar, -76-0 cmHg)
A vacuum pump
4. INSTRUCTIONS
I
CREAT A VACUUM
1)
Drain coolant from radiator.
2)
Select a suitable-sized rubber bush, fitting it
to the lower part of tool with gauge, and
connect it to the radiator filler neck.
3)
When tightening the screw on the tool the rubber
bush will expand to fit securely the filler neck.
4)
Connect the vacuum pump to the tool.
5)
Connect the shop air to the top of the vacuum
pump, as in Fig. 1.
Open the valve to create a vacuum in the
6)
cooling system.
7)
When the gauge reading falls into the range
between -0.7 to -0.8 Bar (-50 to -60 cmHg),
turn off the valve.
Fig. 1
Three (3) rubber bushes (OD 35, 39.5, 44mm)
A coolant hose
II
REFILL COOLANT
1)
Disconnect the shop air and the vacuum pump.
2)
Connect the coolant hose to the quick coupler,
as in Fig. 2
3)
Put the hose into a container filled with
pre-mixed coolant.
Make sure there is sufficient amount of coolant
to be refilled into the cooling system.
4)
Turn on the valve and the coolant would flow
into the radiator. The refilling process is done
when the gauge reads zero. Make sure if the
coolant is refilled with an adequate amount.
5)
Disconnect the shop air and hose. Clean all the
residual coolant in the devices before storage.
Fig. 2
www.9circleint.com