- ページ 11
サービス機器 Autool CT-200のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Autool CT-200 14 ページ。 Injector cleaner & tester
Autool CT-200 にも: マニュアル (18 ページ), ユーザーマニュアル (14 ページ)
to the pressure specified by the factory to be inspected, most
Beyond the original factory pressure of 10%), observe
whether the injector is dripping.
After the test is completed, the system will automatically stop
and beep with a buzzer.
Note:
The general requirement is no more than one drop (or
according to technical standards) within one minute.
The system internal setting time defaults to 1 minute.
19
On-Vehicle cleaning
The hose line connection of the engine with return hose is
shown as in Fig.06.
Disconnect the connections of fuel supply hoses (C
、
fuel return hoses (A
B) of the engine fuel system (wrap the
connector with towel when disconnecting the connector).
Choose proper connectors and connect them to the B end
and C end separately, and then connect the other ends to
corresponding return hose and outlet hose of the unit. See
Fig.06.
Connect the disconnected other ends (A、 D) with proper
hose, or remove the fuel pump fuse, or disconnect the power
cable of engine fuel pump.
Fig.06
1-C100 Injector Cleaner & Tester; 2-Engine; 3- Fuel-return hose
from engine; 4- Fuel-inlet hose to engine; 5-Auto filter; 6-Engine
fuel supply hose; 7-Engine fuel return hose; 8- Auto fuel pump;
9-Auto tank
、
D) and
20