- ページ 5

建設機械 Dynaset HPW-DUSTのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Dynaset HPW-DUST 20 ページ。 High pressure dust suppression systems

5
HPW90 dust double, PC-SAE 1"-24V, D200105500
DUAL WATER CIRCUIT SYSTEM (DWC) components ready for installation and for instantly use, including
following components:
HPW-PUMP 1., PRESSURE REDUCING VALVE 2.2, FLOW LIMITING VALVE 2.3 and SOLENOID VALVE 2.4.
(spraying On) In OC-hydraulic systems, HPW-pump is operated under constant hydraulic pressure. The output
water flow and eventually hydraulic flow is rated by the size of installed water nozzles.
The flow limiting valve is adjusted at factory to the throughput required by high power dust suppression.
HOSE
HAND SPRAY
PISTOL
PRESSURE RELIEF VALVE
2.4 SOLENOID VALVE (HIGH PRESSURE)
2.3 FLOW LIMITING VALVE
ON / OFF -VALVE (CONTINUOUS)
HPW-DUST HIGH PRESSURE SUPPRESSION SYSTEMS
HPW-DUST DOUBLE BASIC COMPONENTS
PV-SAE
2.3
FILTER
ELEMENT
2.4
2.2
HPW200 dust double-DWC, D200105350
HPW200/30-45
NOZZLES:
2 x 6504 (12 lpm 65°)
2 x 6502 (6,4 lpm 65°)
- PUSH AND PULL
BUTTONS
- INDICATOR LAMP
- SOLENOID PLUGS
- CONTROL WIRING
April 2014 JLe
HPW90/150-85
1.