a. Assign a subject number to the test subject.
b. Enter the name of the test subject, if desired. This field is not required.
c. Enter the remaining subject information.
d. In the "Subject Notes" and "Medical Conditions" fields, you may record information about the
test subject. (Note: Avoid using commas or carriage returns in these fields as they will be lost
upon transfer to Excel.)
e. Click on the "Create Trial" button. This action saves the subject information so that the next
time you want to download data from the same subject, the subject information can be opened.
The subject information is also saved to a subject database.
4. Pressing "Create Trial" opens a window titled "Subject # -- Trial".
a. Enter a short string in the "Trial ID" window. This can be a number or a string of letters that
identify the particular test that was performed.
b. Enter the name of the test supervisor and the pod number found on the back of the pod.
c. In the "Trial Notes" field you may record any information about the test. (Note: Avoid using
commas or carriage returns in these fields as they will be lost upon transfer to Excel.)
d. In the "Desired Output" field, it is suggested that you leave the "All Activity Data" option
selected.
5. Make sure that the pod is in upload mode. The display should read "UPLd". If the pod display reads
"DATA", press and hold both buttons simultaneously for 1 s until the display reads "UPLd".
6. Make sure that the AMP Link is plugged into the USB port and that it is "breathing".
7. Click on the "DOWNLOAD" button on the "Trial Information" window in AMP Ware.
8. Messages regarding the download progress will appear in the black window. After the message
"SUCCESSFUL", AMP Ware will automatically launch MS® Excel to display the data. Wait as Excel
generates the workbook to display the data, this can take up to 20 s. Enable macros if prompted. Then a
window will pop up informing you of the filename and the directory where the data is saved. The
filename has the following format:
subj#_trialstartdate_trial_ID.xls, for example:
subj1300_16-06-03_trial_8.xls.
The data is saved in a directory that is automatically created on the hard disk called C:\AMPDATA, and
in a sub-directory called Subject_#. Where "#" represents the subject number.
9. The "Overview" tab of the workbook contains information about the data presented and the layout of the
workbook.
10. All the normal features of Excel are available (e.g. functions, charts, ...), and the data can be saved as a
different name if desired.
11. Save the workbook before closing it to avoid being prompted to enable macros the next time you open
the workbook. (Note: After the first time, it does not matter whether or not you enable the macros.)
12. To open the data later, either double-click on the file in Windows Explorer or use the File > Open
function within Excel.
6.3.2 Downloading Data for an Existing Subject
To download data for a subject for whom a subject file already exists, it is not necessary to re-enter the subject
information, simply use the "Open Subject" button. This feature can also be used to create Subject Information
profiles in advance of collecting data.
Dynastream Innovations Inc.
AMP 331 Instructions for Users
DOCUMENT NO: D00000381 Rev. 0.E
SHEET: 12 of 12