SAFETY FIRST- PRE-INSTALLATION AND IMPORTANT WARNINGS
A. Make sure none of the components were damaged during shipping before installing this outdoor fire pit
or fire pit table. Refer to the FIRE PIT/TABLE CLEARANCE TO COMBUSTIBLES section on pg.4, to ensure
the surrounding area is properly sized for safe installation.
B. The fire pit/table is for outdoor use only. Do not install or use this appliance inside a building, garage, or
any other enclosed area, including recreational vehicles and/or boats. This unit must be installed so that
the vent opening at the base of the unit remains clear and free of any obstruction at all times.
C. CHECK GAS TYPE (natural gas or propane): Check the unit burner components to verify that the gas sup-
ply you intent to use is compatible with the components supplied with the unit. If the gas supply is differ-
ent, please contact David Cooke Industries LLC.
D. DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS
EXCEEDED. Gas type and pressure must be checked prior to installation and use as follows:
For a natural gas fire pit/table: Supply Pressure: Minimum: 3.5" W.C.; Maximum: 7.0" W.C.
Outlet Pressure: 3.5" to 5.0" W.C.
For a propane gas fire pit/table: Supply Pressure: Minimum: 8.0" W.C.; Maximum: 15.0" W.C.
Outlet Pressure: 10.0" to 12.0" W.C.
E. Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (Btu/hr)
for the unit's respective gas type.
F. All natural gas fire pits/tables must have an emergency gas shut-off valve located on the premises
(commonly located on the gas supply line for the building—please refer to local Building Code). An addi-
tional gas supply shut-off valve should be installed in or near the fire pit/table for maintenance and safety
(it is recommended to shut off supply gas when fire pit/table is not in use).
G. The fire pit/table and its flame height adjustment valve must be disconnected from the gas supply piping
system during any pressure testing of that system at pressure in excess of 1/2 psi (3.5 kPa). This is neces-
sary to ensure that the fire pit/table valve, regulator and components are not damaged.
H. Gas-Supply plumbing requirements: Apply only joint compounds (i.e., yellow plumber's tape) that are re-
sistant to all gasses on all male pipe fittings. Make sure to tighten every joint securely. Do not use joint
compound to connect flare fittings, as it is not necessary and could compromise functionality. Bring the
gas supply pipe up from beneath the table base near it's center (if applicable to unit).
I. Select a location with good drainage that allows easy access for installation and maintenance of the fire
pit/table.
WARNING:
It is the installer's responsibility to ensure a safe installation and to educate the end user as to
proper operation of the unit. This manual shall be left with the owner/operator of this unit for reference.
WARNING:
FOR REMOTE CONTROL USE: To prevent accidental start-up from unwanted RF (radio frequency)
signals it is the responsibility of the end user to turn off power to electric outlet (via wall switch or breaker)
for the remote control receiver when the fire-pit/table is not in use .
WARNING:
It is the responsibility of the installer to follow ALL LOCAL CODES concerning the installation and
operation of the fire pit. In the absence of local codes, please follow:
Fixed piping system: The National Fuel Gas Code, ANSI Z223.1/NFPA 54 or International Fuel Gas Code.
Electrical ground: The National Electrical Code, ANSI/NFPA 70.
OPERATING THE FIRE PIT/TABLE SAFELY AND IMPORTANT WARNINGS
A. This appliance should be inspected before use. It is imperative that the control compartment, burner and
circulating air passageways of the appliance are kept clean.
B. Improper installation and placement of the fire pit/table and decorative media WILL IMPAIR ITS EFF-
CEINCY AND MAY CAUSE THE UNIT TO MALFUNCTION.
C. This appliance is only intended for operation in temperatures above 32 degrees F. Do not operate fire pit
in windy or poor weather conditions. Temperate, calm weather conditions are optimal for fire pit/table
use.
D. When shutting off the fire pit/table ensure the CONTROL VALVE IS IN THE FULL OFF POSITION.
E. DO NOT sit or place any part of the body, clothing, or other flammable material on or near the fire pit/
table. Every time you use the unit, make sure that the area around the unit is clear and free from com-
bustible materials. The Fire Pit should never be covered when lit.
DCI LLC All Rights Reserved: For technical support call (951)-805-0314