- ページ 15

製氷機 COPERTINA inglese 0612のPDF 使用方法と警告をオンラインで閲覧またはダウンロードできます。COPERTINA inglese 0612 15 ページ。 Automatic modular ice-cube maker

MODELS WITH DAILY PRODUCTION OF 300 kg (Fig. 13):
• switch off appliance and cut off power supply with the switch (6 in Fig. 4) fitted at the installation
stage
• remove front left-hand panel by unscrewing fixing screws
• remove knob that holds filter in place
• remove filter and keep it at a distance from the appliance
• remove dust from filter by blowing with compressed air
• replace filter in its seat and secure with knob
• refit front left-hand panel, and secure it with screws

9.3 CLEANING AND SANITIZING OPERATIONS

A cleaning and sanitizing kit specifically designed for this appliance is available from your
dealer.
Do not use corrosive substances to remove limescale from the appliance, because this will
invalidate the warranty, and may cause serious damage to the materials and components of the
appliance.
Do not use jets of water to clean the appliance.
All cleaning operations must be carried out only after the electric power and water supplies
have been disconnected, as described previously, by professionally qualified and authorized
personnel.
Follow the instructions given in the cleaning and sanitizing manual supplied with the appliance.
IMPORTANT:
all the ice produced during the first 5 cycles after cleaning and sanitizing operations, and
any ice already in the bin, must be eliminated
when the appliance is cleaned and sanitized, its bin must also be cleaned and sanitized
Complete sanitizing can only be carried out only by the Authorized Technical Service Centres, and must
be done regularly depending on the conditions of use of the appliance, the chemical and physical
features of the water, and after every period in which the appliance has remained at a standstill for any
length of time.
You are advised to ask your dealer to draw up a scheduled maintenance contract that will cover the
following:
• cleaning the condenser
• cleaning the filter located on the water supply solenoid valve
• cleaning the ice-tray
• checking the charge of coolant gas
• checking the operating cycle
• sanitizing the appliance
If you do not intend to use the appliance for a certain period of time, proceed as follows:
• switch off the electric power source by means of the switch (6 in Fig. 4), and remove the plug of the
appliance from its socket (if any)
• shut off the water supply by turning off the water supply tap(s) (7 in Fig. 4)
• empty the internal basin(s) by raising the flaps and removing the overflow pipe(s)
• empty out the pump body/bodies by blowing compressed air into the pipe(s) that supplies water to the
sprayer bank(s)
• clean filter of water supply solenoid valve as described in chapter 9.1
• clean filter of air condenser (if any) as described in chapter 9.2

10 PERIODS AT A STANDSTILL