- ページ 3

エアコン Galletti 2x1のPDF テクニカル・マニュアルをオンラインで閲覧またはダウンロードできます。Galletti 2x1 12 ページ。 Air conditioning systems

Galletti 2x1 テクニカル・マニュアル
1

THE PATENT

2x1 by Galletti: Evolution in air conditioning
Only someone who has been designing and manufacturing heating and air conditioning units for 45 years could have conceived a product which transcends
the limits of existing technology.
2x1 is an indoor unit for hydronic heating and cooling systems which combines two operating modes in a single unit.
Thanks to an exclusive patented design, 2x1 can function as a heater without the aid of a fan, exploiting instead the principle of natural convection.
In summertime 2x1 offers the advantages of the best fan coil units, cooling, dehumidifying and filtering the air inside the room.
The exclusive patent combines 2 different operating modes in a single unit:
2 different air flow routes inside the unit and 2 distinct heat exchangers make it possible to switch over from natural convection heating to ventilated cooling
or heating.
Heating: 3 operation mode, 5 thermal emission levels:
st
> 1
level - convection heating mode, fan off, flap open. The thermostat
controls the room temperature by acting on the valve (optional), which
interrupts the flow of water. The unit can be shut down immediately by
positioning the air outlet flap in the closed position.
> 2
nd
level - convection heating mode, fan speed set on extra low, flap
open. The thermostat controls the room temperature by acting on the fan
and valve (optional), which interrupts the flow of water.
rd
th /
th
> 3
/4
/5
level - fan coil mode, fan speed on low, medium or high, flap
closed. The thermostat controls the room temperature by acting on the
fan and valve (optional), which interrupts the flow of water.
air
outlet
water
outlet
air
intake
water
inlet
Heating
Static convector mode
Natural convection
COOLING: 1 OPERATING MODE, 4 LEVELS OF COOL AIR DELIVERY
> 1
air
outlet
water
outlet
water
inlet
air
intake
Heating
Static convector mode
EXTRA-LOW operation
Maximum, medium, minimum operation
3
All copying, even partial, of this manual is strictly forbidden.
st
/2
nd
/3
rd
/4
th
level - fan coil mode, fan speed set on EXTRA-LOW, low,
medium or high, flap closed.
The thermostat controls the room temperature by acting on the fan and
valve (optional), which interrupts the flow of water.
air
outlet
water
outlet
water
inlet
air
intake
Heating
Fan coil mode
air
outlet
water
outlet
water
inlet
air
intake
Cooling
Fan coil mode
Extra-low, maximum, medium,
minimum operation
FC66001884 - 00