- ページ 4

産業機器 Emerson Fisher DFAのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Emerson Fisher DFA 12 ページ。 Variable geometry desuperheater

Emerson Fisher DFA 取扱説明書
DFA Desuperheater
August 2013

Installation

WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal
injury.
Personal injury or equipment damage caused by sudden release of pressure may result if the desuperheater is installed
where service conditions could exceed the limits of the pressure class noted on the nameplate. To avoid such injury or
damage, provide a relief valve for over pressure protection as required by government or accepted industry codes and
good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
Table 2. Desuperheater Connection Size
Design
DFA
1. Other standard flanges and connections are also available.
Table 3. Available Valve Connections
Valve Inlet Size, NPS
1,1-1/2, and 2
1. End connection style abbreviations: RF-Raised Face, RTJ-Ring Type Joint, BW-Butt weld, SW-Socket Weld.
2. EN (or other valve body material) ratings and end connections can usually be supplied; consult your Emerson Process Management sales office.
3. Socket weld available on NPS 1, 1-1/2, and 2 only.
Table 4. Fisher DFA Dimensions
DESUPERHEATER BODY FLANGE
Size, NPS
Pressure Rating
3 and 4
1. The NPS 4 DFA requires a 4.00 inch minimum mounting I.D. Contact your Emerson Process Management sales office for NPS 3 DFA minimum mounting I.D.
2. For different centerline to flange face distances Contact your Emerson Process Management sales office.
Table 5. Fisher DFA Installation Dimensions
("D" DIMENSION)
DESUPERHEATER
BODY FLANGE SIZE,
NPS
3 and 4
4
Steam Line Size, NPS
8 - 60
ASME Pressure Rating Raised-Face
Flange(2)
CL150-2500
(1)
INLET CENTERLINE TO OUTLET FLANGE FACE
mm
CL150-1500
152
CL2500
178
PIPE LINE
Size, NPS
mm
8
332
10
358
12
384
14
400
16
425.4
18
451
20
477
22
502
24
527
30
600
Size, NPS
3 or 4
(1,2,3)
Inlet
RF, RTJ, BW, and SW
E
(2)
Inches
6
7
("B" DIMENSION)
INSERTION LENGTH
Inch
13.00
14.25
15.25
15.75
16.75
17.50
17.75
17.75
17.75
17.63
Instruction Manual
Steam Line Connection
ASME Pressure Rating Raised-Face Flange(1)
CL150-2500
Connection
Outlet
F
INLET FLANGE FACE TO OUTLET CENTERLINE
mm
229
241
("T" DIMENSION)
T-HEIGHT
mm
222
222
222
222
222
216
222
222
222
219
D103643X012
(1,2)
RF
(2)
Inches
9
9.5
Inch
8.75
8.75
8.75
8.75
8.75
8.50
8.75
8.75
8.75
8.63