Weight to be Dosed
1
0.00
(kg)
x
OFF
Dosed Weight
0.00
o
RESET
Gross weight
Net weight
(kg)
0.00
Pump OFF
9.
If nitrogen flushing is not desired, press the nitrogen Stop button (6).
10.
If you wish to perform a manual nitrogen flush, select the number in the Manual section of the nitrogen screen (7)
while the system is stopped. To do this, tap on the number. A keyboard will appear on the screen. Enter the number
of minutes desired for the system to pump the nitrogen, and then press Manual (7). This operation is done to clean
the equipment or flush the SO
To regulate the dosing speed for the programmed amount of SO
Ensure that the Desired Flow Rate (8) is in the OFF position.
1.
See the Quick Flow dosing at (9). If a faster or slower dosing speed is desired, open or close the nitrogen regulator
2.
(SEE INSTALLATION MANUAL
The low flow alarm can also be activated to have the system sound an alert when the minimum SO
3.
lower than programmed.
To do this, keep the indicator (10) in the ON position and tap on the number. A keyboard will appear, where you
4.
can program the minimum number of kilos/hour for dosing, Low Flow Alarm (10). This may happen when, for
example, the bottle is empty, the outlet valve is closed, an obstruction is present, etc.
2.2 In-line dosing.
Typically, for the in-line dosing mode, the Weight to be Dosed (1) should be in the OFF position, as this procedure is
intended to homogenize the must/wine with a defined dosage of SO
to be Dosed (1) is in the ON position, the system will stop when it reaches the programmed weight.
In-line dosing may be done automatically or manually.
A. Automatic in-line dosing:
1.
Select the ON mode on the Desired Flow Rate (8) section of the screen.
2.
Press the Auto with Pump (11) selector and make sure that the dosing equipment is connected to the winery's
transfer pump (SEE INSTALLATION MANUAL (14)).
3.
In this mode, the system will operate when the transfer pump does. When this happens, a pump icon will appear at
(11).
4.
Next, enter the amount of SO
Dosage (12), and a keyboard will appear where the dosage can be entered.
5.
Next, select the Pump Flow (13) by tapping on the number. A keyboard will appear where the transfer pump flow
can be entered in kilos/hour.
Av. de los Vinos, s/n - P.I.Alces - 13600 Alcázar de San Juan (Ciudad Real) - Tel. +34 926 55 02 00 - Fax +34 926 54 62 54
Version: 1
Dosing
11
Auto. with pump
Nitrogen
6
0.0
min
Automatic
Tare
(kg)
(kg)
0.00
0.00
"S" valve OFF
hose or wine tubing.
2
(5)
).
to be dosed in grams of SO
2
Committed to Enology
Stop
Man. without pump
7
0.0
0.0
min
min
Stop
Manual
12
Pump flow
13
(kg/h)
0.00
:
2
in the wine tubing. Remember that, if the Weight
2
/kilo of must or wine. To do this, tap on the number in
2
OPERATION MANUAL
Date: 07/22/18
Desired Flow Rate
8
0.00
(kg/h)
x
OFF
Low Flow Alarm
10
0.00
x
OFF
9
Quick flow
Dosage
(g/kg)
0.00
0.00
"N" valve OFF
flow rate is
2
4/5
www.agrovin.com