- ページ 9

コントローラー Agrowtek MX3iのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Agrowtek MX3i 13 ページ。 Intelligent reversing motor controller

Limit Switch Wiring

Motors must be wired to include the limit switches in the motor to terminate operation and prevent damage
to a structure in the event the motors are over-run.
The MX3 will not operate the motor relays unless the limit switches are properly connected or terminals jumpered
unless the inputs are inverted as described below.
L1
L2
L3
REPLACE FUSE
MAX 10A
Limit switch inputs operate using the DC input voltage (12-24Vdc) supplied to the switch and returned to
the input terminal.
Limit Switch Defaults
Limit switches are expected to be Normally Closed in the normal range of operation and Open when the
limit is met. The MX3 can be confi gured to operate in the opposite manner with the limit switches in the
Normally Open position during normal operation and Closed when the limit is met.
Invert Limit Switch Inputs
To 'invert' the limit switches to "normally open" type (limit when closed) press the reset button momentarilly.
The limit switches will now work in the opposite manner.
Reset Button
9
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
Vdc
A
B
C
GND
Reverse Limit
Forward Limit