- ページ 7
ウォーター・ディスペンサー Coral 735のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Coral 735 8 ページ。 Ion exchange water softener
Close the stop cock again and then open the inlet and outlet valves to the softener. Press and
hold the regenerate button (4) you should hear the cam rotate and the following display will
appear, when the cycle indicator shows C1 slowly open the stop cock about a quarter of the
way, this will purge the air from the system. When all of the air has been purged from the
Advance the regeneration cycle to the (Refill) position C8 by pressing the set button and the
up arrow! Wait until the cam stops before repeating the operation and continue to do this until
you reach C8. When in C8 this will direct water down through the regenerant line to purge
the air; when all the air bubbles have gone and the glass chamber is full, press the set button
and up arrow to move the cycle onto C0 service position.
Finally turn on a tap after the softener until the water runs clear.
Your softener is now ready to supply your property with soft water. Please bear in mind that
it may take some time for soft water to reach all outlets in your home.
It is advised that you instigate a delayed regeneration for the first night (see below)
Manual Regeneration.
This softener can perform two different types of manual regeneration either immediate or
delayed.
Delayed Regeneration.
Press and release the regeneration button once. The regen symbol will appear and flash on the
display. A single regeneration will start at 2am (preset regen time) if you wish to cancel this
delayed regen simply press the regeneration button again and the symbol will disappear from
the display.
Immediate Regeneration.
To perform an immediate regeneration press and hold the regen button for 5 seconds until the
cam starts to turn and the egg timer shows.
Rear of control panel
Commissioning the Softener
system (water will begin to run steadily from the drain) open the water
supply fully, this will purge the final air from the system.
- 7 -