- ページ 8
ラボラトリー機器 Coralife Turbo-Twist 12xのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Coralife Turbo-Twist 12x 12 ページ。 Uv sterilizer
Coralife Turbo-Twist 12x にも: 取扱説明書 (6 ページ)
Troubleshooting
UVC Lamp
is not working
Water leak
between the
main body and
hose lock nuts
UVC Lamp Replacement
The UVC lamp has a useful life of about 12 months. To ensure
effective performance, replace the UVC lamp once per year.
How to replace the UVC lamp
➀ Disconnect the sterilizer from the power supply. (It is also necessary
to disconnect the power to the water pump.)
➁ Remove the threaded cap to
expose the lamp socket.
SOCKET
➃ Once cool, pull the UVC lamp out
of the socket.
➄ Make sure that the pins of the lamp plugs
into the socket, indicated with a "click".
➅ Reassemble the Turbo-Twist.
7
PROBLEM
• The plug is not connected to
the power supply.
• UVC lamp base is loose.
• The lamp has expired.
• The hose lock nut is loose.
• The O-ring is not in place.
➂ Pull the UVC lamp assembly out of the main body
and allow to cool. (Be careful not to touch the lamp
as it may be hot.)
If troubleshooting steps do not work, please contact
Central Aquatics Tech Support for additional help.
• Connect the plug to the
power supply.
• Carefully push the UVC lamp
onto the socket until a "click"
is heard.
• Replace the UVC lamp.
• Tighten the hose barb or the
hose lock nut.
• Install the O-ring.
UVC LAMP
SOCKET
SOLUTION
UVC LAMP