- ページ 3

バスルーム設備 Galvin Engineering Clinimix CP-BS 100.90.70.20のPDF インストールマニュアルをオンラインで閲覧またはダウンロードできます。Galvin Engineering Clinimix CP-BS 100.90.70.20 5 ページ。 Thermostatic cartridge assembly for progressive mixer (lead safe-brass spline)

Product Installation Guidelines
ADJUSTMENT OF MIX TEMPERATURES (TAP)
1. Close the valve
4. Remove the lower brass ring
(temperature setting ring) and
rotate the brass ring clockwise
to increase temperature or anti-
clockwise to decrease.
© Galvin Engineering Pty Ltd
.
2. Remove top cap, screw
and handle, ensure that
the cartridge is closed.
5. Reposition the upper ring
in the same position – up
against the stop.
Version 1, 11 January 2022, Page 3 of 5
UPPER RING
3. Remove the upper brass ring
(closure setting ring). Make sure the
control rod doesn't rotate.
.
6. Test the set temperature. If the
temperature is acceptable, reposition
the handle (section 6.1), the screw
and the top cap otherwise repeat
from step 3 to 6.
LOWER RING