- ページ 12
計測機器 AGS Mini Merlin CH4COのPDF インストレーション&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。AGS Mini Merlin CH4CO 16 ページ。 Dual gas detector, methane & carbon monoxide gas
AGS Mini Merlin CH4CO にも: ユーザーマニュアル (16 ページ)
Installation & Operation Manual
OPERATION
First Power Up
Supply mains electrical supply and press and hold the touch button for 3 seconds.
The device enters 'sensor stabilisation' phase for approximately 60 seconds – during this period
the screen will display an 'initialisation' message indicating that the device is not yet ready for
gas detection.
To switch your device off - remove or switch off the mains power supply.
Gas Level Display
At dangerous gas levels, the alarm will continuously sound if the buzzer dip-switch is ON.
Only when gas levels are at a safe level will the audible alarm stop.
Audible Alarm Characteristics
NO ALARM – Gas concentration levels are safe. No alarm sound.
PRE- ALARM – Alarm will 'beep' every 15 seconds.
ALARM – Continuous alarm sound.
The alarm will only sound if the Buzzer is switched to ON.
Rev: 12 01-20
There are no provisions to silence this alarm.
AGS Mini Merlin CH4CO
12