- ページ 7

エンクロージャー AFL OptiNID 500のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。AFL OptiNID 500 8 ページ。 Optical demarcation closure

AFL OptiNID 500 取付説明書

ADAPTER PLATE INSTALLATION

1. Attach the adapter plate to the mounting bracket by
pressing in the nylatch plungers.
2. Route the pigtail assembly around the splice tray. Use
the routing rings located on the outer edge of the tray to
help manage the cable. (Figure 6)
DISTRIBUTION CABLE
INSTALLATION –
PLUG AND PLAY
Caution: In order to avoid micro bends or fiber
damage do not over-tighten the tie wraps around
the fiber bundles.
1. For application that utilized the Compression Fitting
Kit, determine the appropriate compression fitting for
the application.
2. Install the compression fitting, reference the
Compression Fitting Installation section of this
document.
3. Secure the cable to the retention bracket using a tie
wrap. (Figure 2)
4. Route the distribution cable with one turn around the
splice tray. Use the routing rings located on the outer
edge of the tray to help manage the cable.
5. Use accepted local practice to clean the connector end
face.
6. Plug the distribution cable into the adapter plate as
specified by the local engineering practice.
7.
Repeat steps 3-6 for each additional distribution cable
to be installed. (Figure 7)
Note: A FASTConnect
or FUSEConnect
Splice-On Connector may be
®
installed onto a non-connectorized distribution
cable. Reference the installation instructions
provided with the FASTConnect Mechanical
Connector or FUSEConnect Splice-On Connector.
The document will include the following:
Fiber Preparation
Fiber Termination
Connector Assembly
Mechanical Connector
®
INSTALLATION INSTRUCTIONS
OptiNID
© 2017, AFL, all rights reserved. Revision A, 2.16.2017
Specifications are subject to change without notice.
7
500 Optical Demarcation Closure
®
Figure 6
Figure 7