Possible operating failures and method of repair
In case of any possible failure, use the information found in the table for repair:
Failure
The
engine
There is no petrol in the fuel tank.
cannot be started.
The petrol is old.
The engine is cold. The control of the
carburettor air valve is in "Fully open " position.
The fuel cock lever is in "Closed" position.
The butterfly valve control is in "turtle"
position
The cap of the high-voltage cable is not
attached on the spark plug.
The spark plug has become contaminated
or failed; the free distance between the
electrodes is not properly adjusted.
The
engine
The air valve control is set in the wrong
does
not
position.
smoothly
operate.
There is an improper contact between the
spark plug and cap of the high-voltage
cable.
Old petrol. There is water and dirt in the fuel
system.
Contaminated air filter.
A Blades do
Blades are blocked by stones or larger
not rotate
soil pieces.
The V-belt has worn out or torn.
The clutch cable is wrongly adjusted.
High level of
Fixation of blades has loosened or blades
have got damaged.
vibration
Fixing screws have come loose.
FOR THE CLEARING OF FAULTS NOT TREATED ABOVE, CONTACT THE AUTHORISED
ATTENTION:
SERVICE REPAIR SHOP.
The manufacturer reserves the right to modify the cultivator structure without previous notification for the improvement of
consumer characteristics.

Terms of guarantee

Please keep carefully the letter of guarantee completed by the seller, or the certificate of purchase. The GAMA
GARDEN will provide 12 months' guarantee from the date of purchase. This guarantee is in compliance with the
technological condition and the purpose of use / field of application. The following guarantee instructions will not
influence customer's statutory rights.
Preconditions of the 12 months' guarantee:
The device is used exclusively for private purposes.
The guarantee period will be reduced to half if the machine is used in the commercial sector and in the field of
leasing business.
- Our guarantee is provided under the condition that the machine is handled properly and the instructions given in the
instruction manual are observed.
- The maintenance intervals determined are observed.
- It is forbidden to change the design without permission.
Cause
.
Method of repair
Fill the fuel tank up with clean fresh, lead-free petrol
Drain the old petrol from the fuel tank and fill it with clean
fresh, lead-free petrol.
Put the air valve control in "Fully closed" position.
Put the fuel cock lever in the "Open" position.
Set the butterfly valve control in "rabbit" position
Fasten the cap of the high-voltage cable on the spark
plug.
Clean and replace the spark plug if necessary. Check the
free distance between the electrodes.
Set the air valve control in ("Fully open") position if the
engine has already been operating for 2-5 minutes (has
warmed up) or in «fully closed » position, if it has just
been started.
Attach thoroughly the cap of the high-voltage cable onto
the spark plug.
Drain the old petrol from the fuel tank and fill it up with
clean, fresh, lead-free petrol.
Clean or replace the air filter.
Stop the engine and remove cap of the high-voltage
cable from the spark plug. Clean the blades.
Contact a repair shop for the replacement of the V-belt.
Adjust the clutch cable.
Stop the engine immediately and remove the cap of the
high-voltage cable from the spark plug. Replace failed
components.
Stop the engine immediately and remove the cap of the
high-voltage cable from the spark plug. Tighten or
replace the bolts.
.
.