- ページ 7

プールフィルター Jacuzzi 27842.01のPDF 設置および操作マニュアルをオンラインで閲覧またはダウンロードできます。Jacuzzi 27842.01 18 ページ。 Domestic chlorine generating device

Jacuzzi 27842.01 設置および操作マニュアル
Section 2a – INSTALLATION
Commander II Model JC5
Control Box
CONTROL BOX converts incoming
AC power to a Low Voltage DC current,
which energizes the Cell(s). Set the
Control Box on a vertical surface away
from excessive exposure to heat and
moisture. Use the template to mark and
drill the (4) mounting holes and insert
the screws, leaving a ¼ in. gap. Hang the
control box on the screws and level.
Remove the cover by following the steps
on page 10 to access the mounting
holes to tighten the screws.
RATINGS:
Input Power: 115 VAC (3.0 AC amps)
230 VAC (1.5 AC amps)
50/60 Hz
Output Power: Cell Power 1 (5.0* DC amps)
Cell Power 2 (6.5* DC amps)
Cell Power 3 (8.0* DC amps)
*Indicates nominal amperage output. The dual axis controller will slightly vary the amps to optimize the power to the cell.
The cell and tri-sensor are located in a Patented Automatic Flow Bypass Manifold Assembly. 3.6m (12ft.) of Cell and Tri-Sensor
cords are provided with the unit. Ensure that the manifold is located within that distance from the control box with enough slack to
allow for removal for service or maintenance.
CAUTION: It is suggested to locate the cell downstream of all other equipment and on the pool return line only to avoid over-
saturation conditions of your spa. For applications other than as recommended, contact the factory.

Main Components

Tri-Sensor Assembly
Union
Flow In
ELECTROLYTIC SUPERCELL
receives Low Voltage DC current from
the Power Circuit Board, which initiates
the electrolytic process. This process
converts ordinary table salt (Sodium
Chloride) to 100% Pure Sodium
Hypochlorite (Chlorine Bleach) or
Bromine (with the addition of Sodium
Bromide), which in turn sanitizes your
pool or spa.
See page 8 for salt requirements.
Maximum Output:Equivalent to 0.54 kg (1.19 lbs) of free available chlorine/day
JC5 CELL @ Cell Power Level 3 (8 amps DC)
Cell Life Expectancy: A minimum of 15,000 ampere/hours
Agency Approvals: NSF, ETL us, ETL c, CE
4
Cell for Commander II = JC5
Flow Out
TRI-SENSOR ASSEMBLY
ensures that adequate flow
94.5 L/min (25US Gallons/min)
minimum; salt, 2,8 – 3,2 gm/l
(2800–3200 ppm) ideal range; and
water temperatures, above
15.6°C (60°F) are satisfactory to
prevent abusive conditions for the
cell to operate. See page 10 for
instructions to remove and inspect
the tri-sensor assembly.