Register Number
107
Delimiter.
0: SOF no response
1: SOF w/ response
2: ACK
3: NACK
108
On/Off mode.
1: enable
0: disable
109
Band select; XR-specific setting
110
SubCarriers; 4 decimal concatenated numbers, e.g. set of subcarriers "30 40 50 60" is encoded as 30405060.
111
FCC enable (XXR protocol).
1: enable
0: disable

4.3 Supported Baud Rates

Table 4 defines baud rates, which can be applied to UART using ATS command with register number 37 (conven-
tional register for setting the baud rate).
Example:
ATS37 = 14: baud rate set to 57600
ATS37 = 16: baud rate set to 230400

4.4 Factory Defaults

Following are the default PLC parameters with ASCII pass-through or TP pass-through firmware, which are acces-
sible for modification via AT commands in ASCII pass-through variants.
Table 3. Supported AT Registers (continued)
Table 4. Supported Baud Rates
Mode
0 through 4
5
6
7 and 8
9
10 and 11
Note: These higher baud rates might not be standard allocations
12
13
14
15
16
17
18
Baud Rate
600
1200
2400
4800
9600
14400
19200
38400
57600
115200
230400
375000
625000
SM2400 Serial-to-PLC Adapter User's Guide