- ページ 4
ゲートオープナー Dea LIVI N SeriesのPDF 取扱説明書および警告をオンラインで閲覧またはダウンロードできます。Dea LIVI N Series 18 ページ。
2 PRODUCT DESCRIPTION
Models and contents of the package
The name LIVI/N identifies a series of electromechanical operators for sliding gates with different features as to motor and control
board power supply voltage, capacity, mechanical adjustment of force, electronic clutch and built-in limit switch. All automated models
involve the use of advanced control units (NET series) equipped with anti-crushing sensor, built-in 433 MHz radio receiver, speed control
and slow down in opening and closing. The LIVI/N models are intended primarily for residential / condominium and Semi-intensive/
intensive use depending on the duty cycle foreseen for the automation.
LIVI/N is completed by a set of accessories listed in the "PRODUCT ACCESSORIES" table (page I-7).
LIVI/N is composed of a mechanical gear motor which rotates the driving gear; This gear, coupled to the rack properly installed on
the gate, converts the circular motion of the gear motor into rectilinear motion thus allowing the movement of the gate on its own guide.
Inspect the "Contents of the Package" (Pic. 1) and compare it with your product for useful consultation during assembly.
Transport
LIVI/N is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information
that may be provided on the same box for storage and handling.
3 TECHNICAL DATA
Motor power supply voltage (V)
Absorbed power (W)
Max Thrust (N)
Work cycle (leaf L=5m)
Maximum n° of operations in 24 hour (leaf L=5m)
Built-in capacitor (µF)
Operating temperature range (°C)
Motor thermal protection (°C)
Opening speed (m/min)
Weight of product with package (Kg)
Sound pressure emitted (dBA)
Protection degree
NET24N
Power supply (V)
Rated power transformer (VA)
Fuse F2 (A) (transformer)
Batteries
Fuse F1 (A) (batteries input)
24V operators outputs
Warning: The above values are calculated by taking the maximum power
supplied by the respective processors. In absolute terms, the maximum
current for each output should not exceed 10A when using a single motor
and 7A when using 2 motors.
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
OPERATOR
6N - 403N
9N - 803N
230 V ~ ±10% (50 Hz)
320
450
340
490
18 cycles/hour
11 cycles/hour
60
40
8
12,5
140 °C
160 °C
10
11
12,5
CONTROL BOARD
230 V ~ ±10% (50 Hz)
Power supply (V)
80 VA (230/22V)
Fuse F2 (A)
1A
Fuse F1 (A)
2x 12V 1,3A
230V operators outputs
15A
Auxiliaries power supply output
1x 5A
Safety devices power supply output
"Warning" output
Electric lock output
230V Flashing light output
24 V
(24V_AUX + 24V_ST =
max 200mA)
24V Flashing light output
24 V
max 15 W
24V
max 5W or max
Operating temperature range (°C)
1 art. 110
Receiver frequency
24 V
max 15W
Transmitters type of coding
-20÷50 °C
433,92 MHz
Max remote controllers managed
HCS fix-code - HCS rolling
code - Dip-switch
100
6/24N/F-
6/24N/F
BOOST
24 V
80
210
240
22 cycles/hour
60
-
-20÷50 °C
-
16
12
< 70
IPX4
NET230N
230 V ~ ±10% (50 Hz)
5A
160mA
2x 500W (ou 1x 600W)
24 V ~
(24V_AUX + 24V_ST
= max 200mA)
24V
230 V ~ max 150W
max 1 art. 110 or 24V
output max 5W configurable
230 V ~ max 40W
24 V
max 100mA (for led
flashing light) art. LED24AI or
open gate warning light/courtesy
light
-20÷50 °C
433,92 MHz
HCS fix-code - HCS rolling code -
Dip-switch
100
9/24N/F
110
260
18 cycles/hour
40
10
EN-3