12.
Install Electronics Module:
a. Insert the single tab on the electronics module into the single tab at the bottom of the mounting plate.
b. Tilt the module upward and secure the top two tabs into the mounting plate (Fig. 10a).
13.
Attach Connectors:
Secure the following connectors to the circuit board as shown (Fig. 13a and 13b Detail).
a. Secure the mortise lock body assembly connector (10-pin).
b. Secure the mortise keypad/card reader connector (14-pin).
Note: Connectors go on only one way. Do not force and do not offset connector.
Be sure they are seated (completely flush).
IMPORTANT: Door must remain open duing installation. Use door stop.
Fig. 13a
Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Installation Instructions (Continued)
Detail 12b
16
Fig. 12a
From
Outside
Trim
From
Lockbody
Fig. 13b Detail