- ページ 16

ロックス Corbin Russwin Access 800のPDF 取付説明書をオンラインで閲覧またはダウンロードできます。Corbin Russwin Access 800 16 ページ。 Cl33800 tcac2 series cylindrical lockset
Corbin Russwin Access 800 にも: 取付説明書 (17 ページ), プログラミング指導 (16 ページ)

Corbin Russwin Access 800 取付説明書
7) Hard Wiring Instructions
7.6) M35 Power/Remote Unlocking with M861 Propped Door, Forced Door.
784
9VDC
Power Supply
EGND
120 VAC L/N/G
Normally Open
momentary switch
(Remote unlock
- REX option)
NO
C
Red, 2
White, 3
Green, 4
Orange, 5
Blue, 6
Brown, 7
Yellow, 8
C
*NC
DPS Switch
*Wire for switch
contact closure
when door is opened.
Typical locations
shown in Fig. 1
Installation:
1. ElectroLynx™ System Wiring Instructions (refer to Fig. 1 and Fig. 4)
a. Look for the mating part on ASSA ABLOY doors and frames. Then plug in all
connectors as shown in Fig. 4 during product installation.
b. Hard wire forced/propped, hard power and/or remote unlock (REX) as shown.
2. Non-ElectroLynx™ System Wiring Instructions (refer to Fig. 1 and Fig. 4)
a. Cut the 8-pin connector off the Power/Remote Unlock harness and hard wire
to non-ElectroLynx™ door harness. Remote power requires three conductors
and remote unlock requires two conductors.
b. Hard wire door harness to power transfer device.
c. Hard wire forced/propped, hard power and/or remote unlock (REX), as shown.
Door
Outside
Escutcheon
-9 VDC
+9 VDC
Black, 1
Red, 1
Black, 2
White, 3
Green, 4
QC12 Electric Hinge
with 8 and 4-pin connectors,
12 wires and pigtail harness
END OF INSTALLATION INSTRUCTIONS
6 AA batteries MUST be removed from
controller if 784 Power supply is used.
Inside
Escutcheon
Controller
Fig. 4
Power/Remote Unlocking
Forced Door, Propped Door
ElectroLynx Wiring System
ElectroLynx Door Harness
with 8 & 4-pin connectors.
Harness location is
dependent on door type.
15
Remote Power and
REX Connector TB2
Ground Tab
Motor
Connector
TB1
1 2 3 4 5 6 7 8
M35
Power/Remote
Unlocking
Harness
3 2 1
4
Tan
3
Pink
M861 Forced
Door,
Propped Door
Harness
4-pin
connector
REX Input
Connect to
Device
(See page 3)