BATTERY CHARGING WITH SMART
CHARGING STATION
ToughPIX II TRIDENT EDITION is also supplied with
a smart, diagnostic charging station. Not only does
this device charge the battery pack, but it provides
valuable battery status and health information
enabling you to get the most from both your battery
packs and camera.
2.1 Charging a battery pack
1
Insert the CorDEX Instruments NiMH wall charger
into the Charging Station, the green power on light
will be displayed on the Charging Station.
2
Insert a ToughPIX II battery pack into the Charging
Station.
3
The Charging Station will perform a series of
checks on the battery pack, the results of which are
displayed via LEDs on the left hand side.
4
Once the checks are complete, charging will
commence and is indicated by a series of LEDs on
the right hand side of the Charging Station. These
LEDs will cascade in sequence as the battery
charges. Once the charge cycle is complete, all
LEDs will be solid green, the battery can remain in
the Charging Station until needed.
NOTE: if the power is turned off at the socket, or
there is no power when the battery is inserted,
the Charging Station will still function in a basic
diagnostic only mode.
RUGGED
AUTHORITY
2.2 Charging a battery pack
A bank of three LEDs will give an indication of
battery charge status.
Two green/yellow and one green to mimic the
battery gauge bar graph on the camera battery
indicator.
The battery is evaluated under load.
The battery charge LEDs will operate as follows:
Battery
Green
Green/
Green/
Charge
LED 1
Yellow
Yellow
LED 2
LED3
> 90%
GREEN
GREEN
GREEN
90% to 50%
Flashing
GREEN
GREEN
GREEN
50% to 35%
OFF
YELLOW
YELLOW
35% to 25%
OFF
Flashing
YELLOW
YELLOW
< 25%
OFF
OFF
YELLOW
Table 2.2 Battery charge LED operation table
During charging the display will pulse from all OFF to
all ON to indicate charging in progress.
When the charge cycle is complete the battery
charge LEDs will be remain ON at the final charge
state.
If the charger is not connected (ie charging is not
taking place or is complete) the charge LEDs will be
static.
2.3 Diagnostics
The ToughPIX II Charging Station is also designed
to function as a battery diagnostic tool providing
important battery health and status information.
This information is obtained automatically by the
Charging Station when a battery is initially inserted
and takes approximately 5-8 seconds to complete
and should not be interrupted.
Charger Power (Green LED)
Charger Power
Indicates the charger has operational power.
Either a powered NiMH Charger is plugged in OR a TPII battery pack is
powering the unit.
If this LED Is not ON then the charger is not powered.
Battery Health (Amber LED)
Battery recommended for replacement
Battery aging, expect reduced runtime.
Pack temperature (Red
Battery pack temperature outside parameters. This LED will illuminate if the
LED)
battery pack temperature is outside the defined charging range and charging
is disabled. To rectify bring battery and charger within 0-45°C charge
temperature range.
Battery damaged (Red LED)
Indicated if the battery pack is damaged. Battery should be replaced.
Battery fuse (Red LED)
Indicates that the on board battery pack fuse has blown. No charging will
take place. No additional diagnostic data available. Battery must be replaced.
ToughPix II TRIDENT EDITION – User Manual
1
Insert a ToughPIX II battery pack into the Charging
Station and wait for the "Busy" LED to stop flashing
which indicates the battery status information has
been completed.
Battery Status information will now be displayed
on the left hand side LED bank and is defined as
follows: