- ページ 8
フライヤー Dean SR42 GMのPDF インストレーション&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。Dean SR42 GM 14 ページ。 Series sr42, sr52 & sr62 super runner series gas fryers
Dean SR42 GM にも: マニュアル (2 ページ), インストレーション&オペレーションマニュアル (16 ページ)
Manifold Support Bracket
Gas Burner
See Detail A
Orifice
Temperature
Control
1.6 Gas Conversion Components
Use the following components to convert from natural gas to propane and vice-
versa. See Section 1.5 for orifice quantities required for conversion.
Natural Gas to Propane Kit. 826-1817
Bushing, NPT Flush, SR 42 series only
Pilot Orifice (16LP) CE & Non-CE
Burner Orifice, 1.51mm- CE ONLY: All Super Runner
Series
Burner Orifice, 1.51mm (#53)- NON-CE ONLY: SR52
& SR62 Series Only
Burner Orifice, 1.70mm (#51)- NON-CE ONLY: SR42
Series Only
Rating label, contact factory at time of conversion
* Burner orifices listed above are for fryers operating at altitudes of 2000 feet (610 meters) or less. For altitudes
greater than 2000 feet (610 meters), contact the factory for the correct orifice size.
SUPER RUNNER SERIES GAS FRYERS
CHAPTER 1: INSTALLATION INSTRUCTIONS
Frypot Assembly
Pressure
Test
Spigot
Gas
Manifold
Assembly
Typical gas valve, burner and orifice locations (SR42 shown above).
1/2—3/4 Reducer
Bushing
Gas Valve
1.63-inch [41-mm]
Gas Manifold
Burner/Orifice Location
Proper Regulator Must Be Installed
Propane To Natural Gas Kit, 826-2017
Bushing, NPT Flush, SR 42 series only
Pilot Orifice (26N) CE & Non-CE
Burner Orifice, 2.40mm- CE ONLY: All Super Runner
Series
Burner Orifice, 2.53mm (#39)- NON-CE ONLY: SR52
& SR62 Series Only
Burner Orifice, 2.80mm (#35)- NON-CE ONLY: S42
Series Only
Rating label, contact factory at time of conversion
1-6
Burner
1.30-inch [33-mm]
Orifice
Detail A
Propane Applications: