P a g e
| 17
INNOVATIVE HARVEST MANAGEMENT AND SUPPLY CHAIN SOLUTIONS
CHANGE SETTINGS VIA SMS
CHECK THE LOGGER HAS A LOCATION
Check the logger is working by sending this SMS to the SIM's phone number
a. Command - 0000,A00
b. Example response .. Now, 110721 16:40,V,12,56Km/h,97%,
http://maps.google.com/maps?f=q&hl=en&q=22.540103,114.082329
&ie=UTF8&z=16&iwloc=addr&om=1
FIND AND CHANGE THE APN
Obtain the correct APN (
Send SMS to the SIM's phone number
i. Command : 0000,A21, 2,117.20.3.69, 11000,REPLACE WIITH APN,,
ii. e.g "0000,A21, 2,117.20.3.69, 11000,Telstra.internet, ,"
iii. Expected response will be "IMEI,A21,OK" where IMEI is the serial number for the
logger.
CHANGE TIME INTERVAL
SMS Set:
0000,A12,interval,times
SMS Get:
IMEI,A12,OK
Description:
Interval is in unit of 10 seconds.
Interval=0,stop tracking by time interval.
Max time interval= 65535*10 seconds
Times = 0,track by interval continuously;
Times = [1,65535], set how many times(reports) from the tracker with the
specified interval.
Agtrix Pty Ltd
Unit 6, 2 Bonanza Drive, Billinudgel NSW 2483, PO Box 63, New Brighton NSW 2483
Tel +61 (0)2 6680 1309 Email
) for the Mobile provider
Access Point Name
Web:
www.agtrix.com
ABN 67103038508