- ページ 10

ストーブ Dean Hembury 8 SEのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Dean Hembury 8 SE 17 ページ。

DEFRA screw and close combustion manifold.
The Hembury 8 SE is supplied with a DEFRA screw fitted and must be left in place when
using the stove in smoke controlled areas. This screw can be removed when installed in a non-
smoke controlled area.
Screws marked (F) in the above picture are for securing a direct air manifold.
Pre – Lighting Check and Commissioning
Check all Building Regulations have been adhered to.
The baffle plate is in the right position.
A smoke test has been done to check the chimney is clear.

Data Plate

All stoves are numbered and performance marked on a data plate which is found on a swinging
arm located at rear of the stove.

Air Vent

Under part J of building regulations an air vent of the appropriate size must be fitted for all
stoves with a kw rating of over 5kw.
Very air tight properties designed with air permeability less than or equal to 5.0 m3/ (h.m2) per
hour, an air vent will need to be fitted for all kilowatts.
It must be considered when fitting air vents that it is taken into account any other appliance
fitted within the room.
10