室内暖炉 Majestic FSUV30のPDF 設置および住宅所有者向け操作説明書をオンラインで閲覧またはダウンロードできます。Majestic FSUV30 16 ページ。

FSUV20/30 Vent Free Gas Heater
Optional Fan Kit FK24
WHEN INSTALLED, THE HEATER MUST BE
ELECTRICALLY GROUNDED IN ACCOR-
DANCE WITH LOCAL CODES OR, IN THE
ABSENCE OF LOCAL CODES IWTH THE
NATIONAL ANSI/NFPA NO. 70.
NOTE: 110/120 electric power is required to operate
blower (fan).
Be sure to leave sufficient excess wire in case minor
adjustments are required.
Any electrical re-wiring of this fan must be
done by a qualified electrician.
Turn off all power before hook-up.
It will be easier to install the fan before
f i r e - p a r t s . c o m
connecting the gas line to the fireplace.
Temperature
Sensor
Speed
Control
Black
White
Ground
Fig. 11 FK24 fan wiring.
1. Open front access door panel by pulling forward on
handle.
2. Install the fan through the opening at the back of
the pedestal, with the outlet pointed up and the fan
mounting bracket facing the back of the fireplace. The
fan mounts over two studs which hold the fan just below
the firebox floor. Hold the fan in place with the two nuts
provided. (Fig. 12)
3. Locate the fan speed control/junction box on screw
studs provided on base of the fireplace. Tighten with
keps nuts.
4. Install thermal sensor element on screw studs located
to the right of the gas valve on the burner base.
5. Plug in grounded service cord to a convenient wall-
receptacle.
14
Accessories
Fan
FP394
WIRING DIAGRAM
11/20/96
Thermal Sensor
Location
HS114
Fig. 12 FK24 fan location.
Optional remote control units are available to control
different functions of the appliance.
Model
MRC1
MRC2
MRC3
IMT
FP1025
Stud
Valve
Fan Speed Control/
Juction Box

Remote Controls

HS114
FK24 fan
Function(s) Controlled
install
ON/OFF
12/02
ON/OFF and Temperature
ON/OFF and Temperature control
with a digital and a programmable
24 hour clock
Wall mounted thermostat control
Fan is
installed at
the back
of the
pedestal.
10001784