Commissioning - Testing the System

Connect the shower hose to the unit but do not fit the handset.
Turn on the hot and cold isolating valves, and the electricity-
isolating switch. Place the open end of the hose in the bath or
shower tray.
Mixer Valve
Set the temperature control knob to cold, fully clockwise, and press
Spindle
the 'stop/start' button.
Cold water will run from the hose, and you should allow this to
continue for two minutes after which the control knob should be
returned to the '12 o'clock' position. Allow the water to run for a
few minutes to stabilise the hot water flow, and then check that the
water is at a comfortable showering temperature.
If it is too hot or cold, turn off the electricity-isolating switch, pull
off the control knob, and adjust the brass spindle anti-clockwise
to increase the temperature - clockwise to decrease. Replace the
knob in the '12 o'clock' position, switch the electricity on, and check
the water temperature. Readjust as necessary until a satisfactory
temperature is achieved.
Temperature Adjustment
Pass the shower hose through the hole in the soap dish and, using
the rubber sealing washer supplied, fit the handset to the hose and
place the handset in the handset holder.
Press the Stop/Start button. Water flows from the shower head
under the gravity pressure from the storage tank. The 'Eco' button
allows you to switch from a power shower to a gravity (non-powered)
shower.
Temperature Adjustment
The valve allows the maximum showering temperature to be set
at a safe level, preventing accidental scalding. This setting should
be made during commissioning and will require that the hot water
cylinder is at its normal operating temperature.
IMPORTANT:
The handset must be in the spray mode.
We recommend the reading of User Instructions before proceeding
further. This will familiarise you with the operation of the shower.
Turn the brass mixer valve spindle fully clockwise, and then anti-
clockwise until the black line on the spindle is aligned with the
groove on the mixer body, and fit the control knob in the fully cold
position. Check that it is correctly fitted by turning fully clockwise to
the stop, pull the knob off and check that the black line and groove
are aligned. Adjust if necessary. This sets the shower temperature
to 38-40°C, with the control knob pointing to '12 o'clock', if the
stored hot water is at the recommended 60°C.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisors.