屋外暖炉 Majestic fireplaces ODGSR42ARPのPDF ホームオーナーズ・インストレーション&オペレーティング・マニュアルをオンラインで閲覧またはダウンロードできます。Majestic fireplaces ODGSR42ARP 20 ページ。 Outdoor gas fireplace
Flame Adjustment
For units equipped with Hi/Lo valves, flame adjustment
is accomplished by rotating the Hi/Lo adjustment knob
located near the center of the gas control.
Turn
counterclockwise
to increase
flame height
Fig. 15 Flame adjustment knob for SIT820 valve.
Flame Characteristics
FP390
FLAME ADJUSTMENT KNOB
It is important to periodically perform a visual check of
11/21/96
the pilot and the burner flames. Compare them to the il-
lustrations below (Figs. 16, 17, 18). If any of the flames
appear abnormal call a service person.
20007114
Turn clockwise
to lower
flame height
Red Glow
Fig. 17 ODGSR36A flame appearance.
Fig. 18 ODGSR42A flame appearance.
ODGSR Series Outdoor Gas Fireplace
Fig. 16 Proper pilot flame height.
LG319
LG319
ODUVSR36
log flames
11/24/03 djt
LG320
ELECTRON
IGNITION
3/8"-1/2"
NOVA SIT Pilot
FP581
FP581
NVB-PILOTS
12/4/97
11