- ページ 13

ストリング・マシン Gamma PROGRESSION 600ES-LEDのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Gamma PROGRESSION 600ES-LED 17 ページ。

Gamma PROGRESSION 600ES-LED オーナーズマニュアル

TROUBLESHOOTING TIPS

PROBLEM
String slips in clamps
String slips in gripper
String clamp slips on base
String clamp winged lock knob is difficult to
turn
Electrical system does not function
String tension too tight or too loose
To change the fuse, remove the power cord and pull the fuse holder straight out. Remove the
old fuse from the holder and replace it with the supplied spare. Replace the fuse holder into
the machine and check for proper operation.
For additional assistance, contact Gamma Sports Customer Service at 1-800-333-0337
With time and use, the clamping surfaces of your machine may become oily or dirty and result
in string or clamp slippage while stringing. Periodic cleaning of the following parts is
recommended.
String Clamps
Clean the inside gripping surfaces of the string clamp jaws by inserting a cloth or pipe cleaner
soaked with isopropyl alcohol between the jaws and rub back and forth. If the build-up is
excessive, dismantle the string clamp jaws to expose the gripping surfaces by removing the
adjustment screw. Using a small nylon brush, (such as a toothbrush), scrub the inside surfaces
until all debris is removed. Clean the jaws with isopropyl alcohol and re-assemble.
String Clamp Base
Clean the base of the clamps and the top of the turntable with isopropyl alcohol.
String Gripper
Follow the same procedure for cleaning the string clamps.
Fuse Replacement
CARE and CLEANING
12
SOLUTION
- Adjust gap between jaws
- Clean clamp jaws
- Clean gripper jaws
- Make sure string is wrapped over top
jaw of gripper prior to inserting between
gripper jaws
- Clean base of clamp and top of turntable
- Check for proper position of thrust
bearing in the base of the winged lock
knob
- Check power source
- Check power cord connection
- Check stringing machine fuse
- Call Gamma Sports customer service
- Check tension using a tension calibrator
and adjust machine calibration if
necessary