計測機器 Green GPM-304のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Green GPM-304 2 ページ。 Rpm indicator with scalling

WIRING DIAGRAM
Front panel
RELAY
I / P PULSE
SET
GREEN
GPM - 304
RPM INDICATOR WITH SCALLING
Dimensions
External dimensions
I / P PULSE
RELAY
48
SET
GREEN
GPM - 304
RPM INDICATOR WITH SCALLING
96
10
SPECIFICATIONS
Range
Display
Reset : Auto / Manual
Input
Indications
Set points
Output
Relay contact rating
(Resistive load)
Mechanical life of relay
Electrical life of relay
User programming
Power consumption
Supply voltage
Operating voltage range
Weight
Dimension ( L x W x D )
Ambient humidity
Ambient temperature
Storage temperature
In the pack
Rear panel - Connection diagram
NPN / PNP
RESET
PROXIMITY
SIGNAL
RLY
1
2
3
4
5
6
7
NO
C
NC
24 VDC
OUTPUT
P
9
10
11
12
13
14
15
85 - 265 VAC
INPUT SUPPLY
Panel cutout dimensions
45
90
75
All dimensions are in mm
999 999 RPM
Six digits, 0.4 Inch seven segment LED
Auto reset Time 000.1 Sec to 999.9 Sec
NPN (or) PNP Proximity unit (Selectable)
Input Pulse and Relay ON
Two
One relay, 1 c/o
10 A @ 230 VAC
/ 30 VDC
10 million operation
100.000 operation
3 Keys & Display
4.8 VA
85 - 265 VAC , 50 Hz
+ / -10% from the rated voltage
170 grams
96 x 48 x 75
35 to 85 % RH
-10 to 55 c
-25 to 65 c
RPM Indicator, clamp and instruction manual
GPM - 304
RPM INDICATOR WITH SCALLING
Introduction
8
Thank you very much for purchasing this GREEN product
N
GPM - 304. Please read the instruction manual carefully for
16
the full usage of this product
The unit has passed various quality tests before despatch.
Please check however, at the time of arrival, its model code
and its appearance and ensure that all the contents are provided
and there are no faults, damage etc, to the timer. Please also
ensure that the model code ,which is labeled on the unit,
is identical to the one you ordered.
Precaution for safe use
(1) Use and store the product within the specified
ambient temperature and humidity ranges.
(2) Do not use the product in location subject to vibrations
or shocks. Using the product in such location over a long
period may result in damage due to stress.
(3) Do not use the product in locations subject to dust,
corrosive gases, or direct sunlight
(4) Separate the input signal devices, input signal cables
and the product from the source of noise or high - tension
.
cables producing noise
Wiring Diagram
NPN / PNP
PROXIMITY
SIGNAL
1
9
GREEN MICROELECTRONICS INDIA PVT. LTD.
100 Taskant street, B.R. Puram, Peelamedu,
Coimbatore - 641004.Phone no : 0422 4218101
e
- mail : greenmicroelectronics@airtel
INSTRUCTION MANUAL
1. Our company shall not be liable for any damages, as described
below, caused to both any users and third parties
a) Damages caused by the result of operation of the product.
b) Damages caused by any defects in the product which are
unpredictable for us.
2. The content in this manual are subject to change without any
notice. If you have any suggestion on the matter,
Please do not hesitate to contact us.
(5) The supplied power voltage and load must be within the
rated and specified ranges.
.
(6) Do not use where the water or oil splatter on the Timer
(7) Install a switch or circuit breaker that allows the operator
to immediately turn off the power
RESET
RLY
4
2
3
5
6
7
NO
C
24 VDC
OUTPUT
P
10
11
12
13
14
15
85 - 265 VAC
INPUT SUPPLY
Manufacturer
mail
.in
- www.greenelectronics.in
TM
GREEN
COMPONENTS FOR AUTOMATION
Note
8
NC
N
16