- ページ 2

扇風機 Airflow 9041408のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Airflow 9041408 2 ページ。 Aventa in-line fan with kit
Airflow 9041408 にも: マニュアル (2 ページ)

Airflow 9041408 マニュアル
Installation with flexible ducting
Where flexible ducting is used the diameter must be
maintained with the minimum radius of a bend equal to
the diameter of the ducting. It is good ventilation
practice that the ducting is extended to 90% of its
possible length in order to maintain the best possible
airflow. Ensure that flexible duct connections are not
over tightened to the fan outlet spigot. To maximise
airflow rigid ducting should be used where possible.
The fan and ducting should be installed in accordance
with the requirements of the Domestic Ventilation
Compliance Guide, part of the Building Regulations.
Page 9 of 16
Page 13 of 16
Recommended Best Practice
The Building Regulations 2010, Statutory Instrument
Part 9, paragraph 42, imposes a requirement that
testing and reporting of mechanical ventilation
performance is conducted in accordance with an
approved procedure.
Compliance with this requirement by an assessed and
registered 'Competent Person' should follow a 'Best
Practice' process and adopt air flow measurement,
Method A – The Unconditional Method – using a
suitable UKAS certified measuring instrument.
Generically referred to as a 'Zero Pressure Air Flow
Meter' or 'Powered Flow Meter'.
Further information on this method is detailed in
NHBC Building Regulations Guidance Note G272a
10/13 and BSRIA 'A Guide to Measuring air flow rates'
document BG46/2015
Page 10 of 16
Page 14 of 16
Maintenance
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT
FROM THE POWER SUPPLY BEFORE REMOVING
THE COVER.
When installed according to these instructions the
Aventa in-line range is completely safe. The materials
used do not constitute a hazard.
Cleaning
The external housing of the fan can be wiped with a
damp cloth. Do not use household cleaners containing
abrasives.
Note: Always isolate the fan when cleaning. Never
clean any parts of the fan assembly by immersing in
water or using a dishwasher.
Warning
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
Page 11 of 16
Page 15 of 16
Warranty
Applicable to units installed and used in the United
Kingdom. Airflow Developments Ltd guarantees the
Aventa in-line for 3 YEARS from date of purchase
against faulty material or workmanship. Warranty only
covers the fan, not the reinstallation of this if required.
In the event of any defective parts being found, Airflow
Developments Ltd reserve the right to repair or at our
discretion replace without charge provided that the
unit:
1. Has been installed and used in accordance with the
fitting and wiring instructions supplied with each unit.
2. Has not been connected to an unsuitable electrical
supply.
3. Has not been subjected to misuse, neglect or
damage.
4. Has not been modified or repaired by any person
not authorised by Airflow Developments Ltd
5. Has been installed in accordance with latest
Building Regulations and IEEE wiring regulations by a
recognised competent installer.
Airflow Developments Ltd shall not be liable for any
loss, injury or other consequential damage, in the
event of a failure of the equipment or arising from, or
in connection with, the equipment excepting only that
nothing in this condition shall be construed as to
exclude or restrict liability for negligence.
This warranty does not in any way affect any
statutory or other consumer rights.
Page 12 of 16
UK Head-Office
Czech Republic
Germany
AIRFLOW DEVELOPMENTS Limited
AIRFLOW LUFTTECHNIK GmbH
AIRFLOW LUFTTECHNIK GmbH
Aidelle House, Lancaster Road
organizační složka Praha
Postfach 1208
Cressex Business Park
Hostýnská 520
D-53349 Rheinbach
High Wycombe
108 00 Praha 10
Germany
Buckinghamshire
HP12 3QP
Czech Republic
United Kingdom
Tel:
+44 (0) 1494 525252
Fax :
+44 (0) 1494 461073
Tel:
+42 (0) 2 7477 2230
Tel:
+49 (0) 222 69205 0
Email:
Fax:
+42 (0) 2 7477 2370
Fax:
+49 (0) 222 69205 11
Web:
airflow.com
Web:
airflow.cz
Web:
airflow.de
AIRFLOW DEVELOPMENTS LTD reserve the right in the interest of continuous development to alter any or all specifications without
prior notice.
Page 16 of 16