- ページ 5

家庭用電化製品 Centrometal CSK-TouchのPDF 設置、使用およびメンテナンスに関する技術的な指示をオンラインで閲覧またはダウンロードできます。Centrometal CSK-Touch 8 ページ。 Digital room corrector

Settings
3.2. Views
In the Views menu, you can define the number of views or correctors that can be monitored on this
digital corrector and define the name of each view and assign it a heating circuit that it controls. On
the main screen, depending on the number of views selected, the letters of the view appear in the
menu bar (from A to H, user-assigned names are only visible on the selected screen, not in the
menu bar). If there are more than 2 views, the other views are selected by pressing the "..." menu
(three dots) followed by the other selected views. After clicking on one of the desired views, the
menu bar returns to the possible selection of the first 2 views.
menu bar
3.2.1. No. of views
Selects the number of views or associated room correctors that can be controlled via this digital
corrector. If only this digital corrector exists, the
number 1 must be selected
3.2.x. View A/B/C/D/E/F/G/H
3.2.x.1. View Name
Each view can have a name according to the user's wishes (eg Living Room, Ground floor ...).
3.2.x.2. Heating circuit
Each view must be assigned a heating circuit wich is controled by this view (usually each corrector
controls its own heating circuit).
3.3. Measurement corr.
If the measured temperature on the digital corrector
deviates from the actual room temperature, in this menu the measured temperature on the digital
corrector screen can be corrected.
3.4. Display
Menu for changing the settings of the digital corrector screen.
3.4.1. Background
Selects the background image of the screen that will
be displayed in the normal operation of the corrector.
3.4.2. Backlight
The intensity of the backlight when the corrector is in normal operation or when the settings are
changed.
3.4.3. Weather forecast
If the CM-WiFi box is connected to the Internet, there is below the measured room temperature a
weather forecast for the place where the CM-WiFi box with the currently read temperature from the
server (with the date and hour of reading the current temperature and forecast) and the weather
forecast for today appears and for the next four days (with a minimum and maximum daily
temperature). If the CM WiFi box is not connected to the Internet, the current forecast will not be
displayed on the screen. Then it is recommended to turn off the weather forecast and it will not
longer be displayed on the screen.
Factory:
Weather forecast
12

FIRST TURNING ON

Before turn on the corrector for the first time, it is necessary to configure the heating circuit on the
boiler / CM2K module to which the corrector will be connected. On the boiler control in the
Regulator menu, in the selected heating circuit, in the Corrector menu, it is necessary to select
Digital corrector, and in the menu Addr. dig. corrector, select the desired corrector address (the
same must be selected on the corrector later ) .After starting the corrector for the first time, a menu
will appear on the first screen to select the desired corrector language. The desired language of the
corrector doesn't have to be the same as the language of the boiler. To select the desired language
for the corrector, press the flag of the desired language on the screen.
Factory:
min./max.
No. of views
1
1 / 8
Factory:
min./max.
Heating circuit
0
0 / 255
Factory:
min./max.
Measurement corr.
0
-5.0 / 5.0 °C
After selecting the language on the first screen the indicator flashes that the corrector is not
connected to the boiler. The corrector is adjusted in the menu Menu -> Settings. The menu 3.1.1.
Connection type selects how the corrector will be connected to the boiler / CM2K module. If the
Factory:
min./max.
corrector is connected via the CM-WiFi box (currently the only option), the correct WiFi ID from the
menu Info on the boiler control must be entered in the corrector menu 3.1.2. WiFi ID.
Background
1
1 / 6
Backlight
100
30 / 100 %
setting
ON
OFF / ON
If a specific corrector address is selected on the boiler control unit (if there is more than one digital
corrector, selection of the address of each individual corrector is obligatory), the same address
should be selected on the corrector in the menu 3.1.3. Corrector address.
The corrector can be connected to the boiler / CM2K either directly via the CM-WiFI box or through
another digital corrector. If you want to connect the corrector directly to the boiler / CM2K, in the
menu 3.1.4. Destination address you need to select a WiFi box, and if you want to connect the
corrector to the boiler / CM2K via another corrector (in case the corrector cannot receive the CM-
WiFi box signal ), in the menu 3.1.4. Destination address it is necessary to select the address of
another corrector to be connected.
Technical instructions CSK-Touch
The screen must not be pressed (with your finger ...) when connecting the the room
corrector to the el. power supply. If the screen of the corrector is pressed on arrival
the el. power supply (the screen shows 'Firmware update'), the corrector enters the
software insertion mode which can only be used by authorized serviceman. If the
screen is accidentally pressed, it is necessary to turn off the power on the corrector
and turn it on again without ever pressing the screen to get the corrector ready for
operation.
The CSK-Touch room corrector can be connected to a CM-WiFi box with software
version v.1.11 or later and a Peltec / -L boiler with software version v.2.86 or later.
WiFi ID
Technical instructions CSK-Touch
First turning on
Corrector software
version
Page scroll
Language selection
Boiler sofware version
Software vesrion of
CM-WiFi box
5